Sürdürülebilir Kalkınma Amaçları
Yazarlar
- Çelik, Ilhan(4)
- Karakan, Mehmet(3)
- Süküroglu, Ebru Emine(2)
- Taşdemir, Muharrem(2)
- Çelik, Ayhan(2)
- Şenaslan, Fatih(2)
- Akçay, Serhatcan Berk(1)
- Alsaran, A.(1)
- Alsaran, Akgün(1)
- Aydiner, Kerim(1)
- Azaklı, Z.(1)
- Azaklı, Zeki(1)
- Bayrak, O.(1)
- Beder, Murat(1)
- Bozkurt, Yusuf Burak(1)
- Bülbül, Ferhat(1)
- Celik, A.(1)
- Cicek, Hikmet(1)
- Cuvalci, Olkan(1)
- Efeoglu, İhsan(1)
- Erdemir, Fatih(1)
- Erkan, Ilker(1)
- Gocer, A.(1)
- Hacisalihoglu, I.(1)
- Hamamci, M.(1)
- Hekimoğlu, Ali Paşa(1)
- Inal, Serkan(1)
- Kaplan, Erdar(1)
- Karabudak, Filiz(1)
- Karakan, M.(1)
- Karaman, I.(1)
- Karamis, M.B.(1)
- Keleş, Ayşenur(1)
- Khan, M Adam(1)
- Nair, F.(1)
- Purcek, G.(1)
- Purcek, Gencaga(1)
- Savas, S.(1)
- Savaşkan, T.(1)
- Savaşkan, Temel(1)
Yayınlar
- MakaleAçık Erişim2025Scopus SJRQ2The effect of high SiC ratio on the physical, mechanical, tribological and corrosion behavior of Al2024 alloy matrix composites fabricated by powder metallurgy
Beder, Murat; Varol, Temel; Akçay, Serhatcan Berk; Çuvalcı, Hamdullah; Erdemir, Fatih; Khan, M Adam; Yıldız, Uğur Temel
Reinforcing materials used in the production of metal matrix composites are used to improve the properties of the final composite. However, the compatibility between matrix and reinforcement and the reinforcement ratio directly affects the properties of the composite material. For this reason, low reinforcement ratios are preferred in many studies on ceramic particle reinforced composites. Unlike conventional studies, in this study, the effects of 10 wt%, 20 wt% and 40 wt% SiC content on the microstructure, dry wear properties and corrosion properties of Al2024 matrix composites were investigated. θ phase content became higher as the SiC content was increased. Hardness values increased with increasing SiC reinforcement. The highest value (307.68 HB) was obtained for the composite with 40 wt% SiC reinforcement, an increase of more than 100%. A decrease in volume loss with increasing SiC reinforcement was observed in the friction and wear tests. For 5 N of load and 1200 m of sliding distance, it was found that an addition of 40 wt% of SiC particles in Al2024 matrix results decrease in volume loss by almost 722%.
AtıfScopus8WoS7OpenAlex7İncele
- MakaleAçık Erişim2024Scopus SJRQ3Influence of nickel addition on the microstructure, mechanical, and wear properties of Zn-40Al-2Cu alloy; [Einfluss des Nickelzusatzes auf das Gefüge, die mechanischen und die Verschleißeigenschaften der Legierung Zn-40Al-2Cu]
Savaşkan, T.; Azaklı, Z.; Tan, H.O.
To study the influence of nickel addition on the microstructure, mechanical and lubricated wear properties of Zn-40Al-2Cu alloy, one ternary and five quaternary Zn-40Al-2Cu-(0.5-2.5)Ni alloys were made by permanent mold casting. The wear behavior of these alloys was studied using a block-on-cylinder type test machine, after examining their microstructural and mechanical features. The microstructure of Zn-40Al-2Cu alloy was comprised of aluminum-rich α dendrites and a eutectoid α+η phase mixture. The addition of nickel caused the formation of intermetallic Al3Ni particles in the microstructure of this alloy. As the nickel content of alloys increased their hardness, friction coefficient, working temperature, and average surface roughness increased to certain extents but their strength, ductility, impact resistance, and wear volume decreased. However, the values of their wear volume and average surface roughness exhibited opposite changes with increasing nickel content. The worn surfaces of Zn-40Al-2Cu-Ni alloys were observed to be characterized by smearing and scratching marks. Furthermore, the wear and mechanical properties of these alloys were correlated, and the results were discussed in terms of their microstructural features. Finally, it may be concluded that the nickel addition adversely affects the ductility of Zn-40Al-2Cu alloy but increases its wear resistance.
- MakaleYalnız künye2023Scopus SJRQ4Wear Behavior of Dental Restorative Materials
Sen, Sadri; Zamanlou, Hamid; Karabudak, Filiz; Süküroglu, Ebru Emine
Gradual wear of opposing teeth is a normal phenomenon in human dentition. There is a need for quality dental restorative materials to repair or replace natural teeth to ensure a higher quality of life through dental health. One of the main physiological mechanism that exists in dental materials during normal muscle function is called abrasion. There are two types of that in teeth which are common; Two-body and three-body. If the teeth are contacted directly, it is referred to as two-body abrasion. However, when there is abrasive slurry-like food between the teeth, this abrasive is called to be three-body abrasive. Several types of materials are available in current dentistry for teeth restoration and replacement, and new materials are being promoted every year. Dental specialists need to understand the wear mechanisms of these new types of dental restorative materials, alone or in combination with either enamel or other dental restorative material. The present study evaluates the abrasive resistance of three restorative materials groups: direct composites, indirect composites, and ceramics. To define the resistance of the wear, the authors then perform a micro-wear test on chosen materials. The results show that the wear mechanism is abrasive due to its low hardness compared to zirconia ball. The wear path in the nanohybrid (Grandio (R), 87s% w/w (71s% volume) inorganic nanohybrid filler, BisGMA, UDMA, TEGDMA) sample was smooth and without particles. In this study wear FEM analysis calculated for all models and the answers compared with experimental data.
- MakaleYalnız künye2023Scopus SJRQ3Effect of Isothermal Treatment on Mechanical and Tribological Properties of Alloy Zn – 40% Al – 2% Cu – 2% Si
Savaşkan, Temel; Hekimoğlu, Ali Paşa; Azaklı, Zeki
The effect of isothermal exposure at temperatures from 100°C to 250°C for 8 hours on the structure, mechanical and tribological properties of the Zn – 40% Al – 2% Cu – 2% Si alloy produced by chill casting is studied. The isothermal treatment eliminates dendritic segregation yielding a coarse-grained polyhedral structure containing an α-solid solution with fine inclusions of silicon and zinc-rich phase. Increase in the temperature of the isothermal exposure leads to decrease in the hardness and strength and increase in the ductility, in the coefficient of friction and in the wear magnitude while reducing the average roughness of the alloy surface.
AtıfScopus5WoS5OpenAlex5İncele
- MakaleYalnız künye2023Scopus SJRQ1Enhanced wear resistance and surface properties of oxide film coating on biocompatible Ti45Nb alloy by anodization method
Şenaslan, Fatih; Taşdemir, Muharrem; Çelik, Ayhan; Bozkurt, Yusuf Burak
β-Titanium alloys have become increasingly popular as biomaterials because of their low modulus of elasticity and superior corrosion properties in recent years. β-titanium alloy containing niobium is also a biocompatible and non-toxic material. Among β-Ti alloys, Ti45Nb is one of the most remarkable alloys for its superior properties as a biomaterial. This alloy has superior properties due to low elasticity modulus and non-toxic elements, but its surface properties are inadequate for biomaterial applications. Therefore, various surface treatments are applied to improve the surface properties of these alloys. In this study, an oxide film layer was formed on the Ti45Nb surface under different potential conditions by the anodizing method. The effects of these factors on friction, wear, and contact angle measurements were investigated. The structural properties of the oxide film coated samples were analyzed with XRD and their surfaces and cross-sectional images were observed by SEM. Also, the surface roughness and nanoindentation tests were performed. In this regard, it was determined that oxide film thickness, surface roughness and hardness increased with the increase of anodization potential. The contact angle of the samples decreased with the increase in the anodization potential and the surface tension of the materials increased. The highest nanohardness of about 4.19 GPa was obtained from 150 TA samples. The elasticity modulus of the untreated sample was about 63 GPa, while the anodized samples ranged from an average of 31 to 83 GPa. The wear results revealed that the anodization process improved the wear resistance of the Ti45Nb alloy. As a result, the sample anodized at 200 V for 30 min exhibited optimum surface roughness, morphology and high wear resistance.
AtıfScopus33WoS32OpenAlex32İncele
- MakaleAçık Erişim2021Scopus SJRQ4Wear, Corrosion and Tribocorrosion Behavior of Polyurethane and Polyvinylpyrrolidone Blends as Coating for Corrosion Protection of AISI 316L Stainless Steel
Taşdemir, Muharrem; Şenaslan, Fatih; Çelik, Ayhan
Polyurethanes (PUs) are used across a widely from biomaterials to industrial applications due to their versatile properties. Polyurethane is blended with other polymers to improve their physical and thermal properties. In this study, different concentrations of polyurethane and polyvinylpyrrolidone (PVP) blends were applied to AISI 316L stainless steel using the dip coating method as protection against wear and corrosion. The effects of different concentrations of blends on the mechanical, corrosion and tribocorrosion properties of the AISI 316L stainless steel were investigated. The phase structure of polymer coatings were investigated by X-ray diffraction (XRD), and their surfaces were examined by scanning electron microscopy (SEM). Corrosion and tribocorrosion tests of the polymer coated samples were carried out in 3.5% NaCl solutions. The surface roughness and nanohardness of the polymeric coated samples were also measured. It was found that surface roughness and friction coefficient increased with raised concentration of PVP, while wear and corrosion resistance decreased with the increased of PVP concentration in the coating. As the penetration depth of the PU coated sample increased, the nanohardness and elasticity modulus decreased. Coatings containing PVP up to 25% protected the substrate surface under tribocorrosion conditions in NaCl solutions.
AtıfScopus6WoS5OpenAlex6İncele
- MakaleYalnız künye2021Scopus SJRQ2Investigation of characterization and tribological behavior of composite oxide coatings doped with h-BN and graphite particles on ZA-27 alloy by micro-arc oxidation
Kaplan, Erdar; Sukuroglu, Ebru Emine; Cuvalci, Olkan
This paper investigates the tribological effects of composite oxide coatings grown on ZA-27 surfaces under dry sliding condition. Coating processes were conducted using three different electrolytic solutions through micro-arc oxidation (MAO) method. The base electrolytic solution without any particles as additives was labeled as MAO-Coated, whereas electrolytic solution labeled as Coated-A contained graphite particles and Coated-B contained hexagonal boron nitride (h-BN) particles incorporated into base solution. The morphology of each coated samples were analyzed using a Scanning Electron Microscope (SEM) and X-Ray Diffraction (XRD). The friction and wear tests were conducted using a pin-on-disc tester in order to evaluate the tribological behavior. Results indicated the friction coefficients of both Coated-A and Coated-B samples were lower when compared to that of uncoated ZA-27 alloy. Further comparative studies showed Coated-A samples containing graphite particles resulted in the lowest friction coefficient.
AtıfScopus13WoS12OpenAlex14İncele
- MakaleAçık Erişim2019Scopus SJRQ2Determination of the wear performance of diamond saw blades using inductively coupled plasma
Inal, Serkan; Erkan, Ilker; Aydiner, Kerim
Saw blades are one of the most used cutting tools. They compose the expensive parts of a cutting machine. Therefore, saw-blade wear is an important parameter governing the economy of the cutting process. Significant savings could be made when it is controlled effectively. In this study, a new methodology is employed for the determination of the saw-blade wear in the cutting of two types of marble. Wear of segments is determined by high-precision inductively coupled plasma method. Two types of marbles were used to investigate the wear performance of diamond-impregnated segments of circular saw-blade matrix. Taguchi mixed design L16 (43 21) is used as an experimental design and the results are evaluated statistically with Minitab. The results reveal that the specific wear rate (SWR) of Beige marble increases with the increase of the peripheral speed, traverse speed, depth of cut and down-cut mode operation. Additionally, it is demonstrated that the traverse speed and peripheral speed are the dominant cutting parameters affecting the SWR. It is also seen that similar trends are observed for Onyx marble (excluding peripheral speed). Finally, it is concluded that the proposed models can be effectively used for the estimation of the SWR.
AtıfScopus4WoS2OpenAlex6İncele
- BildiriAçık Erişim2018Tribological Behaviour of Ti:Ta-DLC Films under Different Tribo-Test Conditions
Efeoglu, İhsan; Keleş, Ayşenur; Totik, Yaşar; Cicek, Hikmet; Süküroglu, Ebru Emine; Hamamci, M.; Gocer, A.; Karamis, M.B.; Nair, F.; Savas, S.
Diamond-like carbon (DLC) films are suitable applicants for cutting tools due to their high hardness, low friction coefficient and wear rate. Doping metals in DLC films have been improved its tribological properties. In this study, titanium and tantalum doped hydrogenated DLC films were deposited by closed-field unbalanced magnetron sputtering system onto M2 high speed steels in Ar/N2/C2H2 atmosphere. The friction and wear properties of Ti:Ta-DLC film were investigated under different tribo-test conditions including in atmospheric pressure, distilled water, commercial oil and Ar atmosphere. The coated specimens were characterized by SEM and X-ray diffraction techniques. The bonding state of C-C (sp3) and C=C (sp2) were obtained with XPS. The tribological properties of Ti:Ta-DLC were investigated with pin-on-disc wear test. Hardness measurements performed by micro-indentation. Our results suggest that Ti:Ta-doped DLC film shows very dense columnar microstructure, high hardness (38.2 GPa) with low CoF (μ ≈0.02) and high wear resistance (0.5E-6 mm3/Nm).
AtıfScopus7WoS5OpenAlex8İncele
- MakaleAçık Erişim2017Scopus SJRQ3Influence of Duplex Treatment on Structural and Tribological Properties of Commercially Pure Titanium
Çelik, Ilhan
Titanium and its alloys are widely used in many fields, including aerospace and the chemical and biomedical industries. This is due to their mechanical properties, excellent corrosion resistance, and biocompatibility although they do have poor wear resistance. In this study, a duplex layer was successfully formed on the commercially pure titanium surface by duplex treatments (plasma nitriding and physical vapor deposition (PVD)). In the initial treatment, plasma nitriding was performed on the pure titanium samples and in the second treatment, the nitrided samples were coated with CrN by PVD. The friction and wear properties of the duplex-treated samples were investigated for tribological applications. Surface morphology and microstructure of the duplex-treated samples were analyzed by X-ray diffraction (XRD) and scanning electron microscopy (SEM). In addition, the tribological properties were investigated using pin-on-disc tribometer. A compound layer composed of ϵ-Ti2N and δ-TiN phases and a diffusion layer formed under the compound layer were obtained on the surface of pure titanium after the nitriding treatments. CrN coated on the nitrided surface provided an increase in the surface hardness and in the wear resistance.
AtıfScopus4WoS4İncele
- MakaleAçık Erişim2016Scopus SJRQ3Investigation of structural and tribological properties of duplex surface treated pure titanium
Çelik, I.; Karakan, M.
Commercial pure titanium (CP-Ti) is used in many engineering fields because of its superior properties such as excellent corrosion resistance, high strength/weight ratio, and biocompatibility. However, it is not available at the desired rate, since the CP-Ti has poor wear resistance. For this reason, many surface treatments have been applied to improve the poor tribological properties of the CP-Ti. In this study, duplex surface treatments, which are the combination of treatments of electroless Ni-B coating and plasma nitriding, were applied on the surfaces of the CP-Ti. Structural properties of the different surfaces of the treated materials were investigated using scanning electron microscopy (SEM) and X-ray diffraction (XRD). Microhardness measurements were made for the determination of mechanical properties and the pin-on-disk wear tests were made to determine the tribological properties. It was observed that poor wear resistance of the CP-Ti was improved with duplex surface treatments. The results showed that surface hardness, friction coefficient, and surface roughness of coated samples were better than of uncoated CP-Ti.
AtıfScopus7WoS5OpenAlex6İncele
- MakaleYalnız künye2016Scopus SJRQ2Effect of plasma nitriding treatment on structural, tribological and electrochemical properties of commercially pure titanium
Çelik, Ilhan; Karakan, Mehmet
In this study, plasma nitriding treatment was applied to commercially pure titanium (Grade 2). Structural properties, electrochemical and tribological behaviours of the nitrided pure titanium specimens were comparatively investigated. Microstructure and morphology of the plasma nitrided specimens were analysed by X-ray diffraction and scanning electron microscopy. Furthermore, corrosion tests were conducted in Ringer's solution, which represents a human body environment, to determine electrochemical properties. Then, tribological and frictional properties were investigated using pin-on-disc tribometer, and a micro-hardness tester was used to measure the hardness of the coatings. The results showed that plasma nitrided specimens exhibited higher surface hardness than the untreated specimens did. In addition, the plasma nitrided specimens at 700 °C presented significantly better performance than the other plasma nitrided specimens (at 500 °C and 600 °C) under dry wear conditions. Moreover, corrosion test results showed that corrosion behaviours of untreated and nitrided samples had similar characteristic.
AtıfScopus9WoS6OpenAlex11İncele
- MakaleYalnız künye2016Scopus SJRQ3Effect of chemical Ni – B coating on the structure and tribological properties of plasma nitrided pure titanium
Çelik, Ýlhan; Karakan, Mehmet
The structure and the wear resistance of commercial-purity titanium subjected to plasma nitriding followed by chemical deposition of a Ni – B coating are studied.
AtıfScopus4WoS4OpenAlex4İncele
- MakaleYalnız künye2016Scopus SJRQ1Investigation of structural and tribological properties of electroless Ni-B coated pure titanium
Çelik, Ilhan; Karakan, Mehmet; Bülbül, Ferhat
In the present study, the surface of commercial pure (Grade 2) titanium was coated with electroless Ni-B and, then, it was subjected to heat treatment for an hour at 400°. The surface morphology, microstructure and phase identification were analysed by X-ray diffraction and scanning electron microscope. Wear behaviour characterisation was carried out using a ball-on-disc tribometer. The results of the analyses showed that the electroless Ni-B coating had a significantly amorphous structure in the as-deposited condition. It was also determined that the coating structure crystallised after the heat treatment and wear resistance of pure titanium increased after electroless Ni-B coating. Particularly, upon the heat treatment, it was observed that wear resistance and surface hardness of pure titanium considerably increased.
AtıfScopus50WoS42OpenAlex41İncele
- MakaleYalnız künye2016Scopus SJRQ1Structure and surface properties of Al2O3–TiO2 ceramic coated AZ31 magnesium alloy
Çelik, İlhan
Magnesium and its alloys are the engineering materials which have the potential ability to be able to used widely particularly in the automotive, aerospace and in the biomedical sectors, especially thanks to their features such as lightness, specific strength that they have and biocompatibility. However, due to their poor wear resistance and corrosion resistance, the areas of usage are being restricted. This situation prevents Mg alloys to be used without any surface protection despite their good mechanical properties such as high strength/weight ratio. In this study, plasma spraying method is used to improve the poor corrosion resistance of AZ31 Mg alloy. Al2O3–13 wt% TiO2 (AT13) and Al2O3–40 wt% TiO2 (AT40) composite ceramic coatings were coated successfully on the surfaces of AZ31 Mg samples. The wear properties of the AT13 and AT40 coated samples were investigated for tribological applications. Surface morphology and microstructure of the duplex treated samples were analyzed by scanning electron microscopy (SEM) and X-ray diffraction (XRD). The microhardness value of the uncoated AZ31 Mg alloy is 40±3 HV0.1, while the microhardness values of the AT40 and AT13 coatings are enhanced to 800±39 HV0.1 and 1500±35 HV0.1, respectively.
AtıfScopus58WoS54OpenAlex57İncele
- MakaleYalnız künye2014Scopus SJRQ1Effect of different surface oxidation treatments on structural, mechanical and tribological properties of ultrafine-grained titanium
Çelik, Ilhan; Alsaran, Akgün; Purcek, Gencaga
Four different surface oxidation treatments, so-called, anodizing oxidation (AO), micro-arc oxidation (MAO), plasma oxidation (PO) and thermal oxidation (TO), were applied to ultrafine-grained (UFG) pure titanium produced by equal-channel angular extrusion/pressing (ECAE/P). Before and after all treatments, mechanical, structural and tribological properties were investigated. The strength of pure titanium increased substantially after ECAE process. TiO2 phases included the anatase and/or the rutile formed on the surface of UFG Ti depending on oxidation treatments. High strength of UFG Ti was deteriorated by TO and PO treatments because of the recrystallization occurred at high-temperature, while applications of MAO and AO did not cause a significant decrease in its strength due to the prevention of recrystallization of UFG Ti. All oxidation treatments brought about a remarkable increase in wear resistance of UFG Ti because of the formation of adhered and hard TiO2 film developed on the surface. It was concluded that the AO and MAO treatments could be applied to the UFG Ti without any deteriorations in bulk mechanical and wear properties to obtain biocompatible pure titanium with high strength and excellent wear resistance.
AtıfScopus51WoS47OpenAlex50İncele
- BildiriYalnız künye2011Scopus SJRQ1Hydroxyapatite production on ultrafine-grained pure titanium by micro-arc oxidation and hydrothermal treatment
Alsaran, A.; Purcek, G.; Hacisalihoglu, I.; Vangolu, Y.; Bayrak, O.; Karaman, I.; Celik, A.
In this study, pure-Ti (Grade-2) was severely plastically deformed by equal-channel angular extrusion (ECAE) to improve its strength, and then subjected to micro arc oxidation (MAO) and hydrothermal treatment (HT) to achieve improved surface behavior with hydroxyapatite (HA)-containing titania (TiO(2)) coating. Microstructure, tensile properties and wear behavior of UFG Ti were investigated systematically before and after surface modification. ECAE considerably enhanced the strength of coarse-grained (CG) Ti by forming an ultra-fine grained (UFG) microstructure with high dislocation density. The application of MAO with or without HT did not cause remarkable decrease in strength and ductility of CG and UFG Ti, but resulted in a considerable increase in its wear resistance and osseointegration due to the formation of hard and adhered HA-containing TiO2 coating on the surface. It can be concluded that the use of ECAE plus MAO/HA coating provides a simple and effective procedure to obtain pure Ti with high strength and high wear resistance. The improved bulk and surface properties can make this biocompatible material a good potential candidate for biomedical applications instead of alloys including toxic elements. (C) 2011 Elsevier B.V. All rights reserved.
AtıfScopus61WoS61OpenAlex65İncele

