Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleYalnız künye2022Scopus SJRQ3
    Serum heparanase levels and left atrial/left atrial appendage thrombus in patients with nonvalvular atrial fibrillation

    Yilmaz, Mehmet Fatih; Acar, Emrah; Inanir, Mehmet; Karabay, Can Yucel; Izgi, Ibrahim Akin

    Introduction Data regarding the possible role of heparanase (HPA) in the occurrence of left atrial/left atrial appendage (LA/LAA) thrombus in patients with atrial fibrillation (AF) is lacking. The goal of the present study was to assess the association between plasma levels of HPA and LA/LAA thrombus in AF. Methods A total of 687 patients with nonvalvular AF (NVAF) without anticoagulation therapy were included from January 2016 to June 2019. Serum HPA analysis was performed with a commercially available human ELISA kit. Logistic regression models were used to test for association. Results Serum HPA levels were significantly higher in patients with LA/LAA thrombus than in those without LA/LAA thrombus (270.8 [193.4 +/- 353.2] pg/mL vs 150.3 [125.2 +/- 208.4] pg/mL; P < 0.001). In multivariate analysis, serum HPA remained a significantly independent predictor of LA/LAA thrombus (odds ratio 1.674, 95% confidence interval [CI] 1.339-2.289, P < 0.001). In the receiver operating characteristic (ROC) curve analysis, HPA showed a predictive value with an area under the curve (AUC) of 0.757 (95% CI 0.652-0.810, P < 0.001). The optimal cutoff level for HPA predicting LA/LAA thrombus was 210.7 pg/mL, with a sensitivity of 74.3% and a specificity of 64.8%. Conclusion An elevated HPA level was associated with the presence of LA/LAA thrombus in patients with AF. HPA might portend the risk for the prothrombotic state in AF patients.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfWoS2OpenAlex3
    Web of SciencePubMedİncele
  • MakaleYalnız künye2016Scopus SJRQ2
    Assessment of Left Atrial Mechanics in Patients with Preexcitation Syndrome Scheduled for Catheter Ablation

    Karakoyun, Suleyman; Tanboga, Ibrahim Halil; Gökdeniz, Tayyar; Lazoglu, Zakir; Topçu, Selim; Karal, Huseyin; Aksakal, Enbiya; Sevimli, Serdar

    ObjectivesWe aimed to test the left atrial (LA) mechanics and contraction synchrony by 2D strain imaging, in patients with Wolff-Parkinson-White (WPW) syndrome, before and after radiofrequency catheter ablation (RFCA). MethodsStudy population consisted of 25 patients with WPW scheduled for RFCA and 30 healthy controls. The peak LA strain at the end of the ventricular systole (LAs strain) and the LA strain with LA contraction (LAa Strain) were obtained. To assess LA dyssynchrony, septal versus lateral wall time-to-peak strain measurements were measured. ResultsThere was no difference between the patients with WPW and control subjects with regard to peak LAs and LAa strain. Patients with WPW demonstrated higher global time-to-peak LAs and LAa strain values compared with the control group. Peak LAs strain and LAa strain values, measured before and after the RF ablation of the accessory pathway, were comparable (34.33.92 vs. 34.6 +/- 3.2, P=0.816, 14.7 +/- 2.8 vs. 15.3 +/- 2.3, P=0.052, respectively). Global time-to-peak LAs and LAa strain measurements were significantly shorter after the RFCA compared with the values obtained before the RFCA. However, septo-lateral times to peak LA strain differences were found to be comparable in both WPW versus control and pre- versus postablation groups. ConclusionLA mechanical function assessed by 2D strain imaging was comparable between patients with WPW and control subjects. Patients with WPW had more prominent LA dyssynchrony during atrial pump phase as compared with the controls, a condition which could not improve after successful elimination of the accessory pathway by RFCA.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfWoS3OpenAlex2
    Web of SciencePubMedİncele