Yazarlar

  • MakaleAçık Erişim2026Scopus SJRQ2
    Selective Determination of Trace Co(II) and Cu(II) in Food and Environmental Matrices via Carrier Element-Free Coprecipitation Using a Novel Thiosemicarbazone-Derived Schiff Base

    Bulut, Volkan N.; Demirci, Hamit; Ozdes, Duygu; Gundogdu, Ali; Bektas, Hakan; Soylak, Mustafa; Duran, Celal

    A carrier element-free coprecipitation (CEFC) method was developed for the preconcentration and determination of trace Co(II) and Cu(II) in environmental and food samples using a novel thiosemicarbazone-derived Schiff base ligand (MBITAH). Unlike conventional coprecipitation approaches, the proposed strategy eliminates the need for inorganic carriers, reducing potential interferences and improving selectivity toward the target analytes. Under optimized conditions (pH 7.0, 1.5 mg ligand), quantitative recoveries were achieved with limits of detection of 1.16 and 0.79 µg L⁻1 for Co(II) and Cu(II), respectively. A preconcentration factor of 50 enabled sensitive determination by flame atomic absorption spectrometry (FAAS) with good precision (RSD ≤ 3.7%). The method exhibited good tolerance toward common matrix ions and was validated using certified-reference material (CRM-SA-C Sandy Soil C) and spike/recovery tests, showing agreement with certified values (p > 0.05). Its applicability was demonstrated in sea water, stream water, and food samples (red lentil and bulgur), confirming reliable performance in complex matrices. Compared with previously reported approaches, the proposed CEFC method offers a favorable balance between analytical performance, simplicity, and cost-effectiveness. In addition, greenness assessment using the AGREE tool yielded a score of 0.45, indicating a moderate-to-good level of environmental friendliness.

  • MakaleYalnız künye2024Scopus SJRQ3
    Development of a New and Facile Carrier Element-Free Coprecipitation Procedure for Separation, Preconcentration and Sensitive Determination of Cu(II) and Cd(II) Ions in Water and Vegetable Samples

    Duran, Celal; Ozdes, Duygu; Mentese, Emre; Bektas, Hakan

    A facile and sensitive method predicated on carrier element free coprecipitation (CEFC) using 2-(2-(2-(4-bromobenzyl)-1H-benzo[d]imidazole-1-yl)acetyl)-N-ethylhydrazine-1-carbothioamide (BIMANEC) is reported for trace determination of Cu(II) and Cd(II) in vegetables and water. BIMANEC was used for the first time for the quantitative determination of these trace heavy metals. Flame atomic absorption spectrometer (FAAS) was used for quantitation. The preconcentration conditions were optimized with respect to pH (8.0), BIMANEC mass (4.0 mg), volume of sample (100 mL), standing time (5 min), and centrifugation time and rate (3 min and 2500 rpm). The influence of potentially interfering ions was scrutinized for the recovery of analyte ions. Under the optimum conditions, the limits of detection (LODs) were 0.51 and 2.28 µg L−1 for Cu(II) and Cd(II), respectively. The relative standard deviations were < 5% for both. The recoveries from the spiked vegetable samples were from 94.9 to 102.8% and from the spiked water samples between 93.2 and 101.6%. Consequently the developed new, facile, rapid, and highly efficient CEFC process was employed for the trace determination of Cu(II) and Cd(II).

    AtıfScopus6WoS8OpenAlex7
    ScopusWeb of Scienceİncele