Comparison of two plain radiographic and 3D-based measurement methods for posterior malleolar fragment size in trimalleol ankle fractures

MakaleAçık Erişim
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Aim: The aim of this study is, to compare the posterior malleolar fragment (PMF) sizing between lateral ankleradiography measurement and computer assistted 3D modelling (CA3DM) methodsMethods: Fifty-one patients between january 2015 and november 2018 with posterior malleolar fractured wereincluded in this study. The rate of PMF to the articular surface at the distal end of the tibia was calculated by twodifferent imaging methods by two surgeons. According to posterior fragment size, patients were separated intotwo groups. Group 1 was consisted of posterior fragment size smaller than 15% and group 2 was bigger than15% due to CA3DM.Results: The interobserver correlation (IOC) between two observers and CA3DM was 44.3%. Also the IOCbetween first observer and CA3DM was 35.7% (p<0.05), second observer and CA3DM were 46.6% (p<0.01)and observers was 51.6% (p<0.01). For group 1, IOC between two observers and CA3DM was 41.2% (p<0.05),first observer and CA3DM was 30.6% (p>0.05), second observer and CA3DM was 51.6% (p<0.05) and twoobservers were 45.8% (p<0.05). For group 2, IOC between two observers and CA3DM was 27.9% (p>0.05),first and CA3DM was 18.6% (p>0.05), second observer and CA3DM was 7.1% (p>0.05) and two observers was49% (p<0.05).Conclusion: Our study shows that posterior malleolar fragment size measuring on plain radiography is not a safemethod for bigger fragments and CA3DM method may be a more reliable to assess correct fragment size andalso to analyze fracture morphology. But for fragments ≤15% CA3DM and plain radiographic measures are notstatistically different.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/17947Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.25000/acem.641188Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAltun, Güray
dc.contributor.authorÇatal Reis, Hatice
dc.contributor.authorBayram, Bülent
dc.contributor.authorSaka, Gursel
dc.date.accessioned2026-10-22T10:39:25.246085469Z
dc.date.available2026-10-22T10:39:25.246085469Z
dc.date.issued2020
dc.description.abstractAim: The aim of this study is, to compare the posterior malleolar fragment (PMF) sizing between lateral ankleradiography measurement and computer assistted 3D modelling (CA3DM) methodsMethods: Fifty-one patients between january 2015 and november 2018 with posterior malleolar fractured wereincluded in this study. The rate of PMF to the articular surface at the distal end of the tibia was calculated by twodifferent imaging methods by two surgeons. According to posterior fragment size, patients were separated intotwo groups. Group 1 was consisted of posterior fragment size smaller than 15% and group 2 was bigger than15% due to CA3DM.Results: The interobserver correlation (IOC) between two observers and CA3DM was 44.3%. Also the IOCbetween first observer and CA3DM was 35.7% (p<0.05), second observer and CA3DM were 46.6% (p<0.01)and observers was 51.6% (p<0.01). For group 1, IOC between two observers and CA3DM was 41.2% (p<0.05),first observer and CA3DM was 30.6% (p>0.05), second observer and CA3DM was 51.6% (p<0.05) and twoobservers were 45.8% (p<0.05). For group 2, IOC between two observers and CA3DM was 27.9% (p>0.05),first and CA3DM was 18.6% (p>0.05), second observer and CA3DM was 7.1% (p>0.05) and two observers was49% (p<0.05).Conclusion: Our study shows that posterior malleolar fragment size measuring on plain radiography is not a safemethod for bigger fragments and CA3DM method may be a more reliable to assess correct fragment size andalso to analyze fracture morphology. But for fragments ≤15% CA3DM and plain radiographic measures are notstatistically different.
dc.identifier.doi10.25000/acem.641188
dc.identifier.eissn2564-6567
dc.identifier.endpage15
dc.identifier.issue1
dc.identifier.startpage11
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/17947
dc.identifier.volume5
dc.language.isoen
dc.relation.ispartofArchives of Clinical and Experimental Medicine
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGörüntüleme Bilimi ve Fotoğraf Teknolojisi
dc.subjectOrtopedi
dc.titleComparison of two plain radiographic and 3D-based measurement methods for posterior malleolar fragment size in trimalleol ankle fractures
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex1
rdl.citation.trdizin0
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/1014670
rdl.sdgSDG03
rdl.source.indexTRDIZIN