Automated Model Updating of Historical Masonry Structures Based on Ambient Vibration Measurements

MakaleYalnız künye
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Finite-element (FE) model updating is a very effective procedure for determining the uncertainty parameters in a structural model and minimize differences between experimentally and analytically identified dynamic characteristics. This procedure can be practiced with manual and global/local automatic model updating procedures. Automatic model updating is very popular because of its applicability to all kinds of engineering structures to minimize differences, and its damage localization and structural health monitoring. This paper considers a historical masonry bastion to obtain its dynamic characteristics numerically with the finite-element method and experimentally with ambient vibration tests (AVTs). Sensitivity analyses for the uncertainty parameters and manual and automated model updating to minimize differences are also performed. A castle bastion located in Trabzon, Turkey is selected as an application. The FE model of structure is developed in commercial software. The first three natural frequencies are obtained between 5 and 10Hz, and AVTs are performed under natural excitation using enhanced frequency domain decomposition (EFDD) and subspace structural identification (SSI) techniques. The first three natural frequencies are obtained between 4 and 7Hz. The comparison of analytically and experimentally identified dynamic characteristics shows a close agreement between mode shapes, but 26% difference in natural frequencies. To minimize the difference, the FE model of the bastion is updated using manual and global/local automated updating, changing its material properties of Young's modulus and material density. The maximum differences are reduced from 27 to 3% with manual updating, and to 0.02% with automated model updating.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/16182Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAltunisik, Ahmet Can
dc.contributor.authorOkur, Fatih Yesevi
dc.contributor.authorGenç, Ali Fuat
dc.contributor.authorGünaydin, Murat
dc.contributor.authorAdanur, Suleyman
dc.date.accessioned2026-10-22T10:29:02.814041698Z
dc.date.available2026-10-22T10:29:02.814041698Z
dc.date.issued2018-02
dc.description.abstractFinite-element (FE) model updating is a very effective procedure for determining the uncertainty parameters in a structural model and minimize differences between experimentally and analytically identified dynamic characteristics. This procedure can be practiced with manual and global/local automatic model updating procedures. Automatic model updating is very popular because of its applicability to all kinds of engineering structures to minimize differences, and its damage localization and structural health monitoring. This paper considers a historical masonry bastion to obtain its dynamic characteristics numerically with the finite-element method and experimentally with ambient vibration tests (AVTs). Sensitivity analyses for the uncertainty parameters and manual and automated model updating to minimize differences are also performed. A castle bastion located in Trabzon, Turkey is selected as an application. The FE model of structure is developed in commercial software. The first three natural frequencies are obtained between 5 and 10Hz, and AVTs are performed under natural excitation using enhanced frequency domain decomposition (EFDD) and subspace structural identification (SSI) techniques. The first three natural frequencies are obtained between 4 and 7Hz. The comparison of analytically and experimentally identified dynamic characteristics shows a close agreement between mode shapes, but 26% difference in natural frequencies. To minimize the difference, the FE model of the bastion is updated using manual and global/local automated updating, changing its material properties of Young's modulus and material density. The maximum differences are reduced from 27 to 3% with manual updating, and to 0.02% with automated model updating.
dc.identifier.articlenumber4017126
dc.identifier.doi10.1061/(asce)cf.1943-5509.0001108
dc.identifier.eissn1943-5509
dc.identifier.issn0887-3828
dc.identifier.issue1
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/16182
dc.identifier.volume32
dc.identifier.wosWOS:000418197800006
dc.language.isoen
dc.publisherASCE-AMER SOC CIVIL ENGINEERS
dc.relation.ispartofJOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAmbient vibration test
dc.subjectDynamic characteristics
dc.subjectFinite-element model updating
dc.subjectHistorical masonry bastion
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherARCH DAM
dc.subject.otherIDENTIFICATION
dc.subject.otherBRIDGE
dc.subject.otherCALIBRATION
dc.subject.otherCHURCH
dc.titleAutomated Model Updating of Historical Masonry Structures Based on Ambient Vibration Measurements
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex34
rdl.citation.wos29
rdl.oa.statusclosed
rdl.sdgSDG09
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)