Decaying source model: Alternative approach to determination of true counting rates at X and gamma ray counting systems

MakaleYalnız künyeScopus SJRQ2

Özet

The counting systems consisting of electronic devices are used for detection of radiation due to X or gamma rays. The dead time of the counting system is based on time limitations of these electronic devices. The dead time causes counting losses. Determination of counting rate losses in quantitative and qualitative analysis become a vital step for correction of analysis. Therefore, compensating for counting rate losses is of great importance. These counting rate losses are due to piled up reject time, paralyzable or non-paralyzable system dead time or a combination of these mechanisms. Paralyzable and non-paralyzable models are well-known and frequently used for correction of counting rate losses dependent on the system dead time. However, these two models do not provide enough correction at medium and high counting rates. Therefore, the new models for corrections of counting rate losses are needed. For this reason, both an alternative approach is proposed and a simulation program is coded for counting rate losses in this study. A good agreement is obtained between theoretical model and simulation program.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/15414Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
9
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKarabidak, S.M.
dc.contributor.authorCevik, U.
dc.date.accessioned2026-10-22T10:23:58.991690808Z
dc.date.available2026-10-22T10:23:58.991690808Z
dc.date.issued2013
dc.description.abstractThe counting systems consisting of electronic devices are used for detection of radiation due to X or gamma rays. The dead time of the counting system is based on time limitations of these electronic devices. The dead time causes counting losses. Determination of counting rate losses in quantitative and qualitative analysis become a vital step for correction of analysis. Therefore, compensating for counting rate losses is of great importance. These counting rate losses are due to piled up reject time, paralyzable or non-paralyzable system dead time or a combination of these mechanisms. Paralyzable and non-paralyzable models are well-known and frequently used for correction of counting rate losses dependent on the system dead time. However, these two models do not provide enough correction at medium and high counting rates. Therefore, the new models for corrections of counting rate losses are needed. For this reason, both an alternative approach is proposed and a simulation program is coded for counting rate losses in this study. A good agreement is obtained between theoretical model and simulation program.
dc.identifier.doi10.1016/j.radmeas.2013.07.009
dc.identifier.endpage23
dc.identifier.issn1350-4487
dc.identifier.scopus2-s2.0-84887483580
dc.identifier.startpage18
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/15414
dc.identifier.volume58
dc.identifier.wosWOS:000327283100003
dc.language.isoen
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD
dc.relation.ispartofRadiation Measurements
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAnalog digital converter conversion time
dc.subjectCounting rate
dc.subjectDead time
dc.subjectDecaying source model
dc.subjectMinimum resolving time
dc.subjectPeaking time
dc.subject.classificationNuclear Science & Technology
dc.subject.otherComputer simulation
dc.subject.otherThermoelectric equipment
dc.subject.otherConversion time
dc.subject.otherCounting rates
dc.subject.otherDead time
dc.subject.otherMinimum resolving time
dc.subject.otherPeaking time
dc.subject.otherSource modeling
dc.subject.otherGamma rays
dc.titleDecaying source model: Alternative approach to determination of true counting rates at X and gamma ray counting systems
dc.typeArticle
rdl.citation.openalex9
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)