In situ monitoring of sugar content in breakfast cereals using a novel ft-nir spectrometer

MakaleAçık ErişimScopus SJRQ2
  • SDG 2 · Açlığa Son

Özet

This research demonstrates simultaneous predictions of individual and total sugars in breakfast cereals using a novel, handheld near-infrared (NIR) spectroscopic sensor. This miniaturized, battery-operated unit based on Fourier Transform (FT)-NIR was used to collect spectra from both ground and intact breakfast cereal samples, followed by real-time wireless data transfer to a commercial tablet for chemometric processing. A total of 164 breakfast cereal samples (60 store-bought and 104 provided by a snack food company) were tested. Reference analysis for the individual (sucrose, glucose, and fructose) and total sugar contents used high-performance liquid chromatography (HPLC). Chemometric prediction models were generated using partial least square regression (PLSR) by combining the HPLC reference analysis data and FT-NIR spectra, and associated calibration models were externally validated through an independent data set. These multivariate models showed excellent correlation (Rpre ≥ 0.93) and low standard error of prediction (SEP ≤ 2.4 g/100 g) between the predicted and the measured sugar values. Analysis results from the FT-NIR data, confirmed by the reference techniques, showed that eight store-bought cereal samples out of 60 (13%) were not compliant with the total sugar content declaration. The results suggest that the FT-NIR prototype can provide reliable analysis for the snack food manufacturers for on-site analysis.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14841Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/app10248774Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
15
WoS
14
OpenAlex
14
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAykas, Didem Peren
dc.contributor.authorBall, Christopher
dc.contributor.authorMenevseoglu, Ahmed
dc.contributor.authorRodriguez-Saona, Luis E.
dc.date.accessioned2026-10-22T10:23:13.060691721Z
dc.date.available2026-10-22T10:23:13.060691721Z
dc.date.issued2020
dc.description.abstractThis research demonstrates simultaneous predictions of individual and total sugars in breakfast cereals using a novel, handheld near-infrared (NIR) spectroscopic sensor. This miniaturized, battery-operated unit based on Fourier Transform (FT)-NIR was used to collect spectra from both ground and intact breakfast cereal samples, followed by real-time wireless data transfer to a commercial tablet for chemometric processing. A total of 164 breakfast cereal samples (60 store-bought and 104 provided by a snack food company) were tested. Reference analysis for the individual (sucrose, glucose, and fructose) and total sugar contents used high-performance liquid chromatography (HPLC). Chemometric prediction models were generated using partial least square regression (PLSR) by combining the HPLC reference analysis data and FT-NIR spectra, and associated calibration models were externally validated through an independent data set. These multivariate models showed excellent correlation (Rpre ≥ 0.93) and low standard error of prediction (SEP ≤ 2.4 g/100 g) between the predicted and the measured sugar values. Analysis results from the FT-NIR data, confirmed by the reference techniques, showed that eight store-bought cereal samples out of 60 (13%) were not compliant with the total sugar content declaration. The results suggest that the FT-NIR prototype can provide reliable analysis for the snack food manufacturers for on-site analysis.
dc.description.sponsorshipCDME
dc.description.sponsorshipDoug Mooney
dc.description.sponsorshipOhio State University Center for Design and Manufacturing Excellence
dc.description.sponsorshipWyandot Inc.
dc.identifier.articlenumber8774
dc.identifier.doi10.3390/app10248774
dc.identifier.eissn2076-3417
dc.identifier.issn2076-3417
dc.identifier.issue24
dc.identifier.scopus2-s2.0-85104481366
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14841
dc.identifier.volume10
dc.identifier.wosWOS:000602960800001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofApplied Sciences (Switzerland)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBreakfast cereal
dc.subjectFT-NIR
dc.subjectHandheld sensor
dc.subjectNutrition facts label
dc.subjectPLSR
dc.subjectSugar content
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationPhysics, Applied
dc.subject.classificationChemistry
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.classificationPhysics
dc.subject.otherSOLUBLE SOLIDS CONTENT
dc.subject.otherRAPID-DETERMINATION
dc.subject.otherNUTRITIONAL QUALITY
dc.subject.otherDIETARY FIBER
dc.subject.otherSUCROSE
dc.subject.otherSPECTROSCOPY
dc.subject.otherPRODUCTS
dc.subject.otherFORMULAS
dc.titleIn situ monitoring of sugar content in breakfast cereals using a novel ft-nir spectrometer
dc.typeArticle
rdl.citation.openalex14
rdl.citation.scopus15
rdl.citation.wos14
rdl.oa.statusgold
rdl.oa.urlhttps://www.mdpi.com/2076-3417/10/24/8774/pdf?version=1607421824
rdl.scopus.quartileQ2
rdl.sdgSDG02
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)