Simplified seismic analysis procedures for elevated tanks considering fluid-structure-soil interaction

MakaleYalnız künye

Özet

This paper presents a review of simplified seismic design procedures for elevated tanks and the applicability of general-purpose structural analyses programs to fluid-structure-soil interaction problems for these kinds of tanks. Ten models are evaluated by using mechanical and finite-element modelling techniques. An added mass approach for the fluid-structure interaction, and the massless foundation and substructure approaches for the soil-structure interactions are presented. The applicability of these ten models for the seismic design of the elevated tanks with four different subsoil classes are emphasized and illustrated. Designers may use the models presented in this study without using any fluid and/or special soil elements. From the models defined here, single lumped-mass models underestimate the base shear and the overturning moment. Because almost all the other assumptions for the fixed base give similar results, any method could be used, but the distributed added mass with the sloshing mass is more appropriate than the lumped mass assumptions for finite-element modelling, and is recommended in this study.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14747Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorLivaoǧlu, R.
dc.contributor.authorDoǧangün, A.
dc.date.accessioned2026-10-22T10:23:05.073568845Z
dc.date.available2026-10-22T10:23:05.073568845Z
dc.date.issued2006
dc.description.abstractThis paper presents a review of simplified seismic design procedures for elevated tanks and the applicability of general-purpose structural analyses programs to fluid-structure-soil interaction problems for these kinds of tanks. Ten models are evaluated by using mechanical and finite-element modelling techniques. An added mass approach for the fluid-structure interaction, and the massless foundation and substructure approaches for the soil-structure interactions are presented. The applicability of these ten models for the seismic design of the elevated tanks with four different subsoil classes are emphasized and illustrated. Designers may use the models presented in this study without using any fluid and/or special soil elements. From the models defined here, single lumped-mass models underestimate the base shear and the overturning moment. Because almost all the other assumptions for the fixed base give similar results, any method could be used, but the distributed added mass with the sloshing mass is more appropriate than the lumped mass assumptions for finite-element modelling, and is recommended in this study.
dc.identifier.doi10.1016/j.jfluidstructs.2005.12.004
dc.identifier.endpage439
dc.identifier.issn1095-8622
dc.identifier.issue3
dc.identifier.scopus2-s2.0-33645778761
dc.identifier.startpage421
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14747
dc.identifier.volume22
dc.language.isoen
dc.relation.ispartofJournal of Fluids and Structures
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectElevated tanks
dc.subjectFluid-structure interaction
dc.subjectSimplified procedures
dc.subjectSoil structure interaction
dc.subject.otherFinite element method
dc.subject.otherFluid structure interaction
dc.subject.otherMathematical models
dc.subject.otherSoil structure interactions
dc.subject.otherStructural analysis
dc.subject.otherTanks (containers)
dc.subject.otherFluid-structure-soil interaction
dc.subject.otherSeismic analysis
dc.subject.otherSimplified procedures
dc.titleSimplified seismic analysis procedures for elevated tanks considering fluid-structure-soil interaction
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex139
rdl.citation.scopus126
rdl.oa.statusclosed
rdl.source.indexSCOPUS