Performance of AC overlays using geogrids on PCC contraction joints

MakaleAçık Erişim
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

It is widely known that vertical displacements and strains occur on the joints and these cause defects on the asphalt concrete (AC) overlays on existing Portland cement concrete (PCC) pavements. Various approaches were introduced to minimize these defects. In this study, the effect of joint support formed using the geogrid material with grout mortar on the vertical displacement of PCC and the strain at the bottom of the AC layer. Produced layers were exposed to 1,186,000 Equivalent Single Axle Load (ESAL) in an APT (Accelerated Pavement Test) facility and the results were monitored. According to the obtained results, the use of AC overlay reduces vertical displacement in the PCC by 75%. When geogrid reinforced AC overlay was used, an additional reduction in displacement by 41.2% was achieved. Geogrid reinforcement reduced strain values formed at the bottom of the AC layer from 29.5% to 92.5%. The use of geogrid at joints instead of increasing the thickness of the AC layer from 50 to 80 mm resulted a more significant reduction in both strain and displacement. Besides, the usage of a geogrid interlayer instead of increasing the thickness of the AC layer also provided a significant cost reduction of 57.9% in overall cost.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14630Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇelik, Muhammet
dc.contributor.authorSeferoğlu, Mehmet Tevfik
dc.contributor.authorAkpınar, Muhammet Vefa
dc.date.accessioned2026-10-22T10:22:56.312672800Z
dc.date.available2026-10-22T10:22:56.312672800Z
dc.date.issued2021
dc.description.abstractIt is widely known that vertical displacements and strains occur on the joints and these cause defects on the asphalt concrete (AC) overlays on existing Portland cement concrete (PCC) pavements. Various approaches were introduced to minimize these defects. In this study, the effect of joint support formed using the geogrid material with grout mortar on the vertical displacement of PCC and the strain at the bottom of the AC layer. Produced layers were exposed to 1,186,000 Equivalent Single Axle Load (ESAL) in an APT (Accelerated Pavement Test) facility and the results were monitored. According to the obtained results, the use of AC overlay reduces vertical displacement in the PCC by 75%. When geogrid reinforced AC overlay was used, an additional reduction in displacement by 41.2% was achieved. Geogrid reinforcement reduced strain values formed at the bottom of the AC layer from 29.5% to 92.5%. The use of geogrid at joints instead of increasing the thickness of the AC layer from 50 to 80 mm resulted a more significant reduction in both strain and displacement. Besides, the usage of a geogrid interlayer instead of increasing the thickness of the AC layer also provided a significant cost reduction of 57.9% in overall cost.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK, (217M481)
dc.identifier.doi10.1016/j.geotexmem.2021.02.004
dc.identifier.eissn1879-3584
dc.identifier.endpage1065
dc.identifier.issn0266-1144
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85102834476
dc.identifier.startpage1058
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14630
dc.identifier.volume49
dc.identifier.wosWOS:000660941200002
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofGeotextiles and Geomembranes
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAC overlay
dc.subjectAccelerated pavement test
dc.subjectContraction joints
dc.subjectGeogrid reinforcement
dc.subjectStrain
dc.subjectVertical displacement
dc.subject.classificationEngineering, Geological
dc.subject.classificationGeosciences, Multidisciplinary
dc.subject.classificationEngineering
dc.subject.classificationGeology
dc.subject.otherConcretes
dc.subject.otherDefects
dc.subject.otherGeosynthetic materials
dc.subject.otherGrouting
dc.subject.otherMortar
dc.subject.otherPavements
dc.subject.otherPortland cement
dc.subject.otherReinforcement
dc.subject.otherStrain
dc.subject.otherContraction joints
dc.subject.otherExposed to
dc.subject.otherGeogrid reinforcement
dc.subject.otherOverall costs
dc.subject.otherPortland cement concrete pavements
dc.subject.otherSingle-axle
dc.subject.otherStrain values
dc.subject.otherVertical displacements
dc.subject.otherasphalt
dc.subject.otherconcrete
dc.subject.othergeogrid
dc.subject.otherperformance assessment
dc.subject.otherCost reduction
dc.titlePerformance of AC overlays using geogrids on PCC contraction joints
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex3
rdl.citation.scopus2
rdl.citation.wos2
rdl.oa.statushybrid
rdl.oa.urlhttps://doi.org/10.1016/j.geotexmem.2021.02.004
rdl.scopus.quartileQ1
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)