Optimization insulation thickness and reduction of CO2 emissions for pipes in all generation district heating networks

MakaleAçık ErişimScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 13 · İklim Eylemi

Özet

District heating systems are provided solutions for the increasing energy problems in high-population cities. Energy costs go up depending on increasing heat loss in DHS's distribution network. Heat loss from the network consists of 5–20% of transferred energy, and this loss is higher than the other losses in the heating system. In the study, heat losses from the pipes such as supply-return pipes, hot water and circulation pipes into heat canals are investigated based on energy, exergy, economic and environmental. Optimum insulation thicknesses, energy savings, reduction of CO2 emissions, the first investment costs and payback periods of the pipes in the network of all-generation district heating systems are investigated by using Life Cycle Cost Analysis (LCCA) method for fuel types like natural gas, fuel oil and coal. Optimum insulation thicknesses are calculated for different nominal sizes of pipes and various insulation materials such as glass wool, and rock wool for the different climatic zones. According to the results of the study, the heat losses from pipes in the 4th generation DHS network are decreased between 38.19% and 33.33% from the warmest climate zone to the coldest climate zone according to the 3rd generation. Energy savings, reduction of CO2 emissions, payback periods and optimum insulation thickness values of supply and return pipes in the network are respectively changed between 7.80–98.86 $/m, 39.61–322.32 kg CO2/year, 0.028–0.38 years and 0.025–0.0105 m depending on various fuel types, insulation materials, nominal size pipes, climatic zones and all generation types.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/14485Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/00368504221122287Yayıncı resmi DOI adresi
Atıflar
Scopus
18
WoS
13
OpenAlex
15
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTerhan, Meryem
dc.date.accessioned2026-10-22T10:22:45.748714198Z
dc.date.available2026-10-22T10:22:45.748714198Z
dc.date.issued2022
dc.description.abstractDistrict heating systems are provided solutions for the increasing energy problems in high-population cities. Energy costs go up depending on increasing heat loss in DHS's distribution network. Heat loss from the network consists of 5–20% of transferred energy, and this loss is higher than the other losses in the heating system. In the study, heat losses from the pipes such as supply-return pipes, hot water and circulation pipes into heat canals are investigated based on energy, exergy, economic and environmental. Optimum insulation thicknesses, energy savings, reduction of CO2 emissions, the first investment costs and payback periods of the pipes in the network of all-generation district heating systems are investigated by using Life Cycle Cost Analysis (LCCA) method for fuel types like natural gas, fuel oil and coal. Optimum insulation thicknesses are calculated for different nominal sizes of pipes and various insulation materials such as glass wool, and rock wool for the different climatic zones. According to the results of the study, the heat losses from pipes in the 4th generation DHS network are decreased between 38.19% and 33.33% from the warmest climate zone to the coldest climate zone according to the 3rd generation. Energy savings, reduction of CO2 emissions, payback periods and optimum insulation thickness values of supply and return pipes in the network are respectively changed between 7.80–98.86 $/m, 39.61–322.32 kg CO2/year, 0.028–0.38 years and 0.025–0.0105 m depending on various fuel types, insulation materials, nominal size pipes, climatic zones and all generation types.
dc.identifier.articlenumber368504221122287
dc.identifier.doi10.1177/00368504221122287
dc.identifier.eissn2047-7163
dc.identifier.issn0036-8504
dc.identifier.issue3
dc.identifier.pmid36047006
dc.identifier.scopus2-s2.0-85137059077
dc.identifier.startpage368504221122287
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/14485
dc.identifier.volume105
dc.identifier.wosWOS:000850897000001
dc.language.isoen
dc.publisherSAGE Publications Ltd
dc.relation.ispartofScience Progress
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDistrict heating network
dc.subjectlife-cycle cost analysis (LCCA)
dc.subjectLTDH network
dc.subjectoptimum insulation thickness
dc.subjectreduction of CO<sub>2</sub> emisisons
dc.subject.classificationEducation, Scientific Disciplines
dc.subject.classificationMultidisciplinary Sciences
dc.subject.classificationEducation & Educational Research
dc.subject.classificationScience & Technology - Other Topics
dc.subject.otherOPTIMUM INSULATION
dc.subject.otherEXERGY ANALYSIS
dc.subject.otherENERGY
dc.subject.otherSYSTEMS
dc.subject.otherIMPACT
dc.titleOptimization insulation thickness and reduction of CO2 emissions for pipes in all generation district heating networks
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex15
rdl.citation.scopus18
rdl.citation.wos13
rdl.departmentDepartment of Mechanical Engineering, Engineering and Natural Sciences Faculty, 162318Gumushane University, 29100, Gumushane, Turkey
rdl.oa.statusgold
rdl.oa.urlhttps://doi.org/10.1177/00368504221122287
rdl.scopus.quartileQ1
rdl.sdgSDG13
rdl.sdgSDG07
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)