Optimizing compton suppression systems: A parametric monte carlo study of NaI scintillator geometry
Özet
Compton suppression systems are widely used to enhance gamma-ray spectral quality in applications such as nuclear safeguards and environmental radioactivity measurements. Although optimization of high-purity germanium (HPGe) detectors has been extensively reported, the geometric optimization of secondary sodium iodide [NaI(Tl)] scintillation detectors remains less studied. This work investigates the influence of annular and plug NaI(Tl) detector geometry—length, thickness, and radius—on Compton suppression performance using Monte Carlo simulations. Performance is evaluated in terms of the peak Compton suppression factor (CSFpeak) and total Compton suppression factor (CSFtotal). The results show that CSFpeak and CSFtotal increase with plug length (2–10.2 cm) and annular thickness (1–5.85 cm), with saturation observed beyond approximately 8–10 cm and 4–5 cm, respectively, due to reduced incremental photon absorption. The plug detector radius (3.72–5.1 cm) exhibits a nonlinear effect, with optimal performance achieved at 4.55–4.83 cm, beyond which gains are marginal (<5%). Suboptimal geometries (plug length <6 cm, annular thickness <3 cm, plug radius <4.28 cm) result in 20–60% lower suppression performance, increasing Compton continuum contributions in 662 keV spectra. The optimal configuration—plug length of 8–10 cm, plug radius of 4.55–4.83 cm, and annular thickness of 4–5 cm—achieves more than 90% of maximum CSFpeak and CSFtotal while maintaining a balance between performance and detector volume. These results provide quantitative design guidelines for optimizing NaI(Tl)-based Compton suppression systems for improved gamma-ray spectrometry performance.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kaya, Ali | |
| dc.contributor.author | Çelik, Necati | |
| dc.contributor.author | Kaya, Selim | |
| dc.date.accessioned | 2026-10-22T10:22:24.667447911Z | |
| dc.date.available | 2026-10-22T10:22:24.667447911Z | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Compton suppression systems are widely used to enhance gamma-ray spectral quality in applications such as nuclear safeguards and environmental radioactivity measurements. Although optimization of high-purity germanium (HPGe) detectors has been extensively reported, the geometric optimization of secondary sodium iodide [NaI(Tl)] scintillation detectors remains less studied. This work investigates the influence of annular and plug NaI(Tl) detector geometry—length, thickness, and radius—on Compton suppression performance using Monte Carlo simulations. Performance is evaluated in terms of the peak Compton suppression factor (CSFpeak) and total Compton suppression factor (CSFtotal). The results show that CSFpeak and CSFtotal increase with plug length (2–10.2 cm) and annular thickness (1–5.85 cm), with saturation observed beyond approximately 8–10 cm and 4–5 cm, respectively, due to reduced incremental photon absorption. The plug detector radius (3.72–5.1 cm) exhibits a nonlinear effect, with optimal performance achieved at 4.55–4.83 cm, beyond which gains are marginal (<5%). Suboptimal geometries (plug length <6 cm, annular thickness <3 cm, plug radius <4.28 cm) result in 20–60% lower suppression performance, increasing Compton continuum contributions in 662 keV spectra. The optimal configuration—plug length of 8–10 cm, plug radius of 4.55–4.83 cm, and annular thickness of 4–5 cm—achieves more than 90% of maximum CSFpeak and CSFtotal while maintaining a balance between performance and detector volume. These results provide quantitative design guidelines for optimizing NaI(Tl)-based Compton suppression systems for improved gamma-ray spectrometry performance. | |
| dc.identifier.articlenumber | 114209 | |
| dc.identifier.doi | 10.1016/j.radphyschem.2026.114209 | |
| dc.identifier.eissn | 1879-0895 | |
| dc.identifier.issn | 0969-806X | |
| dc.identifier.scopus | 2-s2.0-105043537542 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/14223 | |
| dc.identifier.volume | 249 | |
| dc.identifier.wos | WOS:001819795200001 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier Ltd | |
| dc.relation.ispartof | Radiation Physics and Chemistry | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Compton suppression system | |
| dc.subject | Gamma-ray spectrometry | |
| dc.subject | HPGe | |
| dc.subject | Monte Carlo simulation | |
| dc.subject | NAI | |
| dc.subject.classification | Chemistry, Physical | |
| dc.subject.classification | Nuclear Science & Technology | |
| dc.subject.classification | Physics, Atomic, Molecular & Chemical | |
| dc.subject.classification | Chemistry | |
| dc.subject.classification | Physics | |
| dc.subject.other | Gamma ray spectrometers | |
| dc.subject.other | Germanium compounds | |
| dc.subject.other | Iodine compounds | |
| dc.subject.other | Optimal systems | |
| dc.subject.other | Phosphorus compounds | |
| dc.subject.other | Radioactivity | |
| dc.subject.other | Radioactivity measurement | |
| dc.subject.other | Scintillation counters | |
| dc.subject.other | Spectrometry | |
| dc.subject.other | Ultraviolet spectroscopy | |
| dc.subject.other | sodium iodide | |
| dc.subject.other | Compton suppression | |
| dc.subject.other | Compton suppression system | |
| dc.subject.other | Gamma rays spectrometries | |
| dc.subject.other | Gamma-rays | |
| dc.subject.other | High purity germaniums | |
| dc.subject.other | Monte Carlo's simulation | |
| dc.subject.other | NAI | |
| dc.subject.other | Performance | |
| dc.subject.other | Spectral quality | |
| dc.subject.other | Suppression systems | |
| dc.subject.other | Article | |
| dc.subject.other | compton effect | |
| dc.subject.other | gamma spectrometry | |
| dc.subject.other | geometry | |
| dc.subject.other | light absorption | |
| dc.subject.other | Monte Carlo method | |
| dc.subject.other | scintillation | |
| dc.subject.other | sensitivity analysis | |
| dc.subject.other | thickness | |
| dc.subject.other | uncertainty | |
| dc.subject.other | Monte Carlo methods | |
| dc.title | Optimizing compton suppression systems: A parametric monte carlo study of NaI scintillator geometry | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 0 | |
| rdl.citation.scopus | 0 | |
| rdl.citation.wos | 0 | |
| rdl.oa.status | closed | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
