An automatic EEG-based sleep staging system with introducing NAoSP and NAoGP as new metrics for sleep staging systems

MakaleYayıncıda açık erişim
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Different biological signals are recorded in sleep labs during sleep for the diagnosis and treatment of human sleep problems. Classification of sleep stages with electroencephalography (EEG) is preferred to other biological signals due to its advantages such as providing clinical information, cost-effectiveness, comfort, and ease of use. The evaluation of EEG signals taken during sleep by clinicians is a tiring, time-consuming, and error-prone method. Therefore, it is clinically mandatory to determine sleep stages by using software-supported systems. Like all classification problems, the accuracy rate is used to compare the performance of studies in this domain, but this metric can be accurate when the number of observations is equal in classes. However, since there is not an equal number of observations in sleep stages, this metric is insufficient in the evaluation of such systems. For this purpose, in recent years, Cohen’s kappa coefficient and even the sensitivity of NREM1 have been used for comparing the performance of these systems. Still, none of them examine the system from all dimensions. Therefore, in this study, two new metrics based on the polygon area metric, called the normalized area of sensitivity polygon and normalized area of the general polygon, are proposed for the performance evaluation of sleep staging systems. In addition, a new sleep staging system is introduced using the applications offered by the MATLAB program. The existing systems discussed in the literature were examined with the proposed metrics, and the best systems were compared with the proposed sleep staging system. According to the results, the proposed system excels in comparison with the most advanced machine learning methods. The single-channel method introduced based on the proposed metrics can be used for robust and reliable sleep stage classification from all dimensions required for real-time applications.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/13285Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11571-020-09641-2Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorMelek, Mesut
dc.contributor.authorManshouri, Negin
dc.contributor.authorKayikcioglu, Temel
dc.date.accessioned2026-10-22T10:21:09.482872646Z
dc.date.available2026-10-22T10:21:09.482872646Z
dc.date.issued2021
dc.description.abstractDifferent biological signals are recorded in sleep labs during sleep for the diagnosis and treatment of human sleep problems. Classification of sleep stages with electroencephalography (EEG) is preferred to other biological signals due to its advantages such as providing clinical information, cost-effectiveness, comfort, and ease of use. The evaluation of EEG signals taken during sleep by clinicians is a tiring, time-consuming, and error-prone method. Therefore, it is clinically mandatory to determine sleep stages by using software-supported systems. Like all classification problems, the accuracy rate is used to compare the performance of studies in this domain, but this metric can be accurate when the number of observations is equal in classes. However, since there is not an equal number of observations in sleep stages, this metric is insufficient in the evaluation of such systems. For this purpose, in recent years, Cohen’s kappa coefficient and even the sensitivity of NREM1 have been used for comparing the performance of these systems. Still, none of them examine the system from all dimensions. Therefore, in this study, two new metrics based on the polygon area metric, called the normalized area of sensitivity polygon and normalized area of the general polygon, are proposed for the performance evaluation of sleep staging systems. In addition, a new sleep staging system is introduced using the applications offered by the MATLAB program. The existing systems discussed in the literature were examined with the proposed metrics, and the best systems were compared with the proposed sleep staging system. According to the results, the proposed system excels in comparison with the most advanced machine learning methods. The single-channel method introduced based on the proposed metrics can be used for robust and reliable sleep stage classification from all dimensions required for real-time applications.
dc.identifier.doi10.1007/s11571-020-09641-2
dc.identifier.eissn1871-4099
dc.identifier.endpage423
dc.identifier.issn1871-4080
dc.identifier.issue3
dc.identifier.pmid34040668
dc.identifier.scopus2-s2.0-85092480482
dc.identifier.startpage405
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/13285
dc.identifier.volume15
dc.identifier.wosWOS:000577060400001
dc.language.isoen
dc.publisherSpringer Science and Business Media B.V.
dc.relation.ispartofCognitive Neurodynamics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectEEG
dc.subjectGeneral polygon
dc.subjectPAM
dc.subjectSensitivity polygon
dc.subjectSleep stage classification
dc.subject.classificationNeurosciences
dc.subject.classificationNeurosciences & Neurology
dc.subject.otherarticle
dc.subject.otherdata analysis software
dc.subject.otherelectroencephalogram
dc.subject.otherelectroencephalography
dc.subject.otherhuman
dc.subject.otherhuman experiment
dc.subject.otherkappa statistics
dc.subject.othermachine learning
dc.subject.othersleep stage
dc.titleAn automatic EEG-based sleep staging system with introducing NAoSP and NAoGP as new metrics for sleep staging systems
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex16
rdl.citation.scopus13
rdl.citation.wos9
rdl.departmentDepartment of Electronics and Automation, Gumushane University, 29100 Gumushane, Turkey
rdl.oa.statusgreen
rdl.oa.statuspreprint
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)