Effect of detuning conditions on the performance of non-traditional tuned mass dampers under external excitation
Özet
The tuned mass damper (TMD) is a widely used passive control device which is attached to a main system to suppress undesired vibration. In this paper, a non-traditional form of TMD system is investigated. Unlike the traditional TMD configuration, the considered TMD system has a linear viscous damper connecting the absorber mass directly to the ground instead of the main mass. There have been some studies on the optimization design of the non-traditional TMD (NT-TMD) for undamped main structures. Those studies have indicated that the NT-TMD provides better performance than the traditional TMD does. When there is a frequency shifting in the structural frequency or tuning frequency of TMD, to the best knowledge of the authors, there has been no study on the performance of the NT-TMD. The main idea of the study is to investigate the effect of frequency detuning on the control performance of the NT-TMD. The optimum parameters of the NT-TMD system and corresponding effectiveness are obtained for different mass ratios of the NT-TMD system. The numerical results indicate that the NT-TMD with high mass ratio provides better robustness to the changes in the target frequency ratio than the traditional TMD.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Araz, Onur | |
| dc.date.accessioned | 2026-10-22T10:20:50.180886233Z | |
| dc.date.available | 2026-10-22T10:20:50.180886233Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | The tuned mass damper (TMD) is a widely used passive control device which is attached to a main system to suppress undesired vibration. In this paper, a non-traditional form of TMD system is investigated. Unlike the traditional TMD configuration, the considered TMD system has a linear viscous damper connecting the absorber mass directly to the ground instead of the main mass. There have been some studies on the optimization design of the non-traditional TMD (NT-TMD) for undamped main structures. Those studies have indicated that the NT-TMD provides better performance than the traditional TMD does. When there is a frequency shifting in the structural frequency or tuning frequency of TMD, to the best knowledge of the authors, there has been no study on the performance of the NT-TMD. The main idea of the study is to investigate the effect of frequency detuning on the control performance of the NT-TMD. The optimum parameters of the NT-TMD system and corresponding effectiveness are obtained for different mass ratios of the NT-TMD system. The numerical results indicate that the NT-TMD with high mass ratio provides better robustness to the changes in the target frequency ratio than the traditional TMD. | |
| dc.identifier.doi | 10.1007/s00419-019-01623-z | |
| dc.identifier.eissn | 1432-0681 | |
| dc.identifier.endpage | 532 | |
| dc.identifier.issn | 0939-1533 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-85074714563 | |
| dc.identifier.startpage | 523 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/13021 | |
| dc.identifier.volume | 90 | |
| dc.identifier.wos | WOS:000493774100001 | |
| dc.language.iso | en | |
| dc.publisher | Springer | |
| dc.relation.ispartof | Archive of Applied Mechanics | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Non-traditional | |
| dc.subject | Optimal design | |
| dc.subject | Robustness | |
| dc.subject | Tuned mass damper | |
| dc.subject | Vibration control | |
| dc.subject.classification | Mechanics | |
| dc.subject.other | Acoustic devices | |
| dc.subject.other | Damping | |
| dc.subject.other | Vibration control | |
| dc.subject.other | Control performance | |
| dc.subject.other | External excitation | |
| dc.subject.other | Non-traditional | |
| dc.subject.other | Optimal design | |
| dc.subject.other | Optimization design | |
| dc.subject.other | Passive control devices | |
| dc.subject.other | Structural frequencies | |
| dc.subject.other | Tuned mass dampers | |
| dc.subject.other | Robustness (control systems) | |
| dc.title | Effect of detuning conditions on the performance of non-traditional tuned mass dampers under external excitation | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.openalex | 27 | |
| rdl.citation.scopus | 27 | |
| rdl.citation.wos | 23 | |
| rdl.oa.status | closed | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
