OUTDOOR DEGRADATION ANALYSES OF SIX DIFFERENT AGED PHOTOVOLTAIC MODULE TECHNOLOGIES UNDER THE ARID-STEPPE CLIMATE CONDITION

MakaleAçık ErişimScopus SJRQ4
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

Outdoor tests of photovoltaics module are crucial both for marketing and for research and technological developments. The electric generation performance and their degradation rates and lifetime are also related to different climatic conditions of the regions. In this work, the outdoor tests are carried out for six different photovoltaic (PV) modules under Arid-steppe Climate condition of Ankara, Türkiye. Their degradation rates are calculated by using linear regression (LR) and year on year (YOY) methods. The comparison between LR and YOY are carried out and with the other performed studies of different regions of world. In addition, it is investigated that how effective the climatic conditions on daily degradation rates. The results obtained are as follows: Mono-Si and Hetero-junction Silicon (HIT) cell modules degradation rates of 0.71/1.56 %/year and 0.84 %/year are respectively obtained by LR method and 0.57/0.90 %/year and 0.85%/year are respectively by YOY method. The degradation rates for Cupper Indium Selenide (CIS), Cupper Indium Gallium Selenide (CIGS) and microcrystalline Silicon/Amorphous Silicon (µc-Si/a-Si) modules have 1.73/1.49 %/year, 11.55/9.52 %/year and 1.48 %/year for LR method and 1.28/1.12 %/year, 9.94/9.53 %/year and 0.99 %/year for YOY method are obtained respectively. It is also obtained for the Polycrystalline Silicon Modules as 1.20/1.86 %/year degradation rates by LR method and 0.79/1.88 %/year degradation rates by YOY method.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/12716Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.47480/isibted.1494143Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
1
WoS
1
OpenAlex
1
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCantürk, Zeynep
dc.contributor.authorÖzden, Talat
dc.contributor.authorAkinoglu, Bulent G.
dc.date.accessioned2026-10-22T10:20:27.068890818Z
dc.date.available2026-10-22T10:20:27.068890818Z
dc.date.issued2024
dc.description.abstractOutdoor tests of photovoltaics module are crucial both for marketing and for research and technological developments. The electric generation performance and their degradation rates and lifetime are also related to different climatic conditions of the regions. In this work, the outdoor tests are carried out for six different photovoltaic (PV) modules under Arid-steppe Climate condition of Ankara, Türkiye. Their degradation rates are calculated by using linear regression (LR) and year on year (YOY) methods. The comparison between LR and YOY are carried out and with the other performed studies of different regions of world. In addition, it is investigated that how effective the climatic conditions on daily degradation rates. The results obtained are as follows: Mono-Si and Hetero-junction Silicon (HIT) cell modules degradation rates of 0.71/1.56 %/year and 0.84 %/year are respectively obtained by LR method and 0.57/0.90 %/year and 0.85%/year are respectively by YOY method. The degradation rates for Cupper Indium Selenide (CIS), Cupper Indium Gallium Selenide (CIGS) and microcrystalline Silicon/Amorphous Silicon (µc-Si/a-Si) modules have 1.73/1.49 %/year, 11.55/9.52 %/year and 1.48 %/year for LR method and 1.28/1.12 %/year, 9.94/9.53 %/year and 0.99 %/year for YOY method are obtained respectively. It is also obtained for the Polycrystalline Silicon Modules as 1.20/1.86 %/year degradation rates by LR method and 0.79/1.88 %/year degradation rates by YOY method.
dc.identifier.doi10.47480/isibted.1494143
dc.identifier.endpage115
dc.identifier.issn1300-3615
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85205295584
dc.identifier.startpage103
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/12716
dc.identifier.volume44
dc.identifier.wosWOS:001346279300008
dc.language.isoen
dc.publisherTurk Isi Bilimi ve Teknigi Dernegi
dc.relation.ispartofIsi Bilimi Ve Teknigi Dergisi/ Journal of Thermal Science and Technology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDegradation rates
dc.subjectLinear regression degradation method
dc.subjectLong-term outdoor testing
dc.subjectPhotovoltaic modules
dc.subjectyear on year degradation method
dc.subject.classificationThermodynamics
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationEngineering
dc.subject.otherGallium compounds
dc.subject.otherLinear regression
dc.subject.otherPhotodegradation
dc.subject.otherPhotovoltaics
dc.subject.otherPolycrystalline materials
dc.subject.otherSilicon wafers
dc.subject.otherClimate condition
dc.subject.otherClimatic conditions
dc.subject.otherDegradation analysis
dc.subject.otherDegradation rate
dc.subject.otherLinear regression degradation method
dc.subject.otherLinear regression methods
dc.subject.otherLong-term outdoor testing
dc.subject.otherOutdoor testing
dc.subject.otherPhotovoltaic modules
dc.subject.otherYear on year degradation method
dc.subject.otherSelenium compounds
dc.titleOUTDOOR DEGRADATION ANALYSES OF SIX DIFFERENT AGED PHOTOVOLTAIC MODULE TECHNOLOGIES UNDER THE ARID-STEPPE CLIMATE CONDITION
dc.typeArticle
rdl.citation.openalex1
rdl.citation.scopus1
rdl.citation.wos1
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/3974114
rdl.scopus.quartileQ4
rdl.sdgSDG13
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)