Effect of detector crystal size on Compton suppression factors
Özet
The geometrical parameters which affect the suppression factor for an HPGe (High Purity Germanium)-NaI Compton suppression spectrometer were studied by a Monte Carlo simulation with the EGS4 system. The spectrums were crated for 5 energy values ranging from 200 keV to 2 MeV. Compton suppression factors (CSFs), the parameters characterizing the system performance, were calculated for different HPGe crystal parameters. It was observed that to obtain better Compton suppressed factors, a laboratory must choose as small HPGe crystal as possible for energy values up to 400 keV. However, for higher energies up to 2 MeV, larger HPGe crystals provide better Compton suppression systems. These findings suggest that the choice of HPGe crystal size can significantly impact the performance of a Compton suppression spectrometer and should be carefully considered in its design and optimization.
Anahtar Kelimeler
- Scopus
- 5
- WoS
- 4
- OpenAlex
- 6
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kaya, Selim | |
| dc.contributor.author | Çelik, Necati | |
| dc.contributor.author | Gök, Abdulkadir | |
| dc.contributor.author | Çevik, Uğur | |
| dc.date.accessioned | 2026-10-22T10:20:19.733964397Z | |
| dc.date.available | 2026-10-22T10:20:19.733964397Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | The geometrical parameters which affect the suppression factor for an HPGe (High Purity Germanium)-NaI Compton suppression spectrometer were studied by a Monte Carlo simulation with the EGS4 system. The spectrums were crated for 5 energy values ranging from 200 keV to 2 MeV. Compton suppression factors (CSFs), the parameters characterizing the system performance, were calculated for different HPGe crystal parameters. It was observed that to obtain better Compton suppressed factors, a laboratory must choose as small HPGe crystal as possible for energy values up to 400 keV. However, for higher energies up to 2 MeV, larger HPGe crystals provide better Compton suppression systems. These findings suggest that the choice of HPGe crystal size can significantly impact the performance of a Compton suppression spectrometer and should be carefully considered in its design and optimization. | |
| dc.identifier.doi | 10.1080/10420150.2023.2258432 | |
| dc.identifier.eissn | 1029-4953 | |
| dc.identifier.endpage | 1462 | |
| dc.identifier.issn | 1042-0150 | |
| dc.identifier.issue | 11-12 | |
| dc.identifier.scopus | 2-s2.0-85171650357 | |
| dc.identifier.startpage | 1449 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/gumushane/12610 | |
| dc.identifier.volume | 178 | |
| dc.identifier.wos | WOS:001069451500001 | |
| dc.language.iso | en | |
| dc.publisher | Taylor and Francis Ltd. | |
| dc.relation.ispartof | Radiation Effects and Defects in Solids | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Compton suppression factor | |
| dc.subject | EGS4 code | |
| dc.subject | HPGe detector | |
| dc.subject.classification | Nuclear Science & Technology | |
| dc.subject.classification | Physics, Fluids & Plasmas | |
| dc.subject.classification | Physics, Condensed Matter | |
| dc.subject.classification | Physics | |
| dc.subject.other | Crystals | |
| dc.subject.other | Geometry | |
| dc.subject.other | Germanium compounds | |
| dc.subject.other | Grain size and shape | |
| dc.subject.other | Intelligent systems | |
| dc.subject.other | Monte Carlo methods | |
| dc.subject.other | Sodium Iodide | |
| dc.subject.other | Compton suppression | |
| dc.subject.other | Compton suppression factor | |
| dc.subject.other | Crystal-size | |
| dc.subject.other | EGS4 code | |
| dc.subject.other | Energy value | |
| dc.subject.other | Germanium crystals | |
| dc.subject.other | High purity germaniums | |
| dc.subject.other | High-purity germanium detector | |
| dc.subject.other | Monte Carlo's simulation | |
| dc.subject.other | Spectra's | |
| dc.subject.other | Spectrometers | |
| dc.title | Effect of detector crystal size on Compton suppression factors | |
| dc.type | Article | |
| rdl.citation.openalex | 6 | |
| rdl.citation.scopus | 5 | |
| rdl.citation.wos | 4 | |
| rdl.oa.status | closed | |
| rdl.scopus.quartile | Q4 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
