Modal parameter identification of RC frame under undamaged, damaged, repaired and strengthened conditions

MakaleYalnız künye
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Structures are built on a design and then damaged in time by natural and manmade effects, repaired and strengthened for reusing. Determination of the structural behavior is very important to avoid future disaster. Operational Modal Analysis has been widely used recently to determine the inherent modal parameters of engineering structures and give significant information about the structural condition. Also, this method can be used to further studies such as model updating, damage detection and health monitoring. In this paper, it is aimed to investigate the changes of modal parameters considering undamaged, damaged, repaired and strengthened conditions using ambient vibration tests. For this purpose, a reinforced concrete frame model having two-floor with two spans in the longitudinal direction considering ½ geometric scales is built in laboratory. Four different cases are considered to emerge the efficiency of this procedure and the undamaged RC model is measured firstly to determine the initial modal parameters. Secondly, the lateral forces are applied to floor levels to obtain the damages, especially in beam-column joints. Thirdly, the damaged model is repaired using injection material and lastly strengthened with Carbon Fiber Reinforcement Polymer. It is also examined that what rate the dynamic characteristics return to back after repairing and strengthening studies by the comparison with undamaged condition? In addition to this the evaluation of carbon fiber reinforcement polymer effectiveness in strengthening for real applications is presented. It is seen that ambient vibration test is enough to identify the modal parameters of engineering structures for different conditions. The modal parameters are decreased distinctly with damages, and reverted almost initial condition with strengthening.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/11602Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAltunişik, Ahmet Can
dc.contributor.authorKarahasan, Olguhan Şevket
dc.contributor.authorGenç, Ali Fuat
dc.contributor.authorOkur, Fatih Yesevi
dc.contributor.authorGünaydin, Murat
dc.contributor.authorKalkan, Ebru
dc.contributor.authorAdanur, Süleyman
dc.date.accessioned2026-10-22T10:19:11.079180098Z
dc.date.available2026-10-22T10:19:11.079180098Z
dc.date.issued2018
dc.description.abstractStructures are built on a design and then damaged in time by natural and manmade effects, repaired and strengthened for reusing. Determination of the structural behavior is very important to avoid future disaster. Operational Modal Analysis has been widely used recently to determine the inherent modal parameters of engineering structures and give significant information about the structural condition. Also, this method can be used to further studies such as model updating, damage detection and health monitoring. In this paper, it is aimed to investigate the changes of modal parameters considering undamaged, damaged, repaired and strengthened conditions using ambient vibration tests. For this purpose, a reinforced concrete frame model having two-floor with two spans in the longitudinal direction considering ½ geometric scales is built in laboratory. Four different cases are considered to emerge the efficiency of this procedure and the undamaged RC model is measured firstly to determine the initial modal parameters. Secondly, the lateral forces are applied to floor levels to obtain the damages, especially in beam-column joints. Thirdly, the damaged model is repaired using injection material and lastly strengthened with Carbon Fiber Reinforcement Polymer. It is also examined that what rate the dynamic characteristics return to back after repairing and strengthening studies by the comparison with undamaged condition? In addition to this the evaluation of carbon fiber reinforcement polymer effectiveness in strengthening for real applications is presented. It is seen that ambient vibration test is enough to identify the modal parameters of engineering structures for different conditions. The modal parameters are decreased distinctly with damages, and reverted almost initial condition with strengthening.
dc.identifier.doi10.1016/j.measurement.2018.04.037
dc.identifier.eissn1873-412X
dc.identifier.endpage276
dc.identifier.issn0263-2241
dc.identifier.scopus2-s2.0-85045700669
dc.identifier.startpage260
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/11602
dc.identifier.volume124
dc.identifier.wosWOS:000433238500031
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofMeasurement: Journal of the International Measurement Confederation
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCarbon fiber reinforcement polymer
dc.subjectDamage
dc.subjectModal parameter
dc.subjectOperational modal analysis
dc.subjectReinforced concrete
dc.subjectRepair
dc.subjectStrengthening
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationInstruments & Instrumentation
dc.subject.classificationEngineering
dc.subject.otherCarbon fibers
dc.subject.otherComposite beams and girders
dc.subject.otherDamage detection
dc.subject.otherDisaster prevention
dc.subject.otherFloors
dc.subject.otherIdentification (control systems)
dc.subject.otherModal analysis
dc.subject.otherPolymers
dc.subject.otherReinforced concrete
dc.subject.otherRepair
dc.subject.otherStrengthening (metal)
dc.subject.otherVibration analysis
dc.subject.otherCarbon fiber reinforcement polymers
dc.subject.otherDamage
dc.subject.otherDynamic characteristics
dc.subject.otherEngineering structures
dc.subject.otherModal parameter identification
dc.subject.otherModal parameters
dc.subject.otherOperational modal analysis
dc.subject.otherReinforced concrete frames
dc.subject.otherStructural design
dc.titleModal parameter identification of RC frame under undamaged, damaged, repaired and strengthened conditions
dc.typeArticle
dspace.entity.typePublication
rdl.citation.openalex38
rdl.citation.scopus40
rdl.citation.wos35
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)