A novel modified PAIR technique using a trocar catheter for percutaneous treatment of liver hydatid cysts: a six-year experience

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

PURPOSE We aimed to demonstrate the success and reliability of a novel puncture, aspiration, injection, and reaspiration (PAIR) technique in liver hydatid cysts. METHODS Percutaneous treatment with ultrasonographic guidance was performed in 493 hepatic hydatid cysts in 374 patients. Patients were treated with a new PAIR technique by single puncture method using a 6F trocar catheter. The results of this novel technique were evaluated with regards to efficacy and safety of the procedure and complication rates. RESULTS Out of 493 cysts, 317 were Gharbi type I (WHO CE 1) and 176 were Gharbi type II (WHO CE 3A). Of all cysts, 13 were referred to surgery because of cystobiliary fistulization. Recurrence was observed in 11 cysts one month later. Therefore, the success rate of the PAIR technique was 97.7% (469/480). Minor complications (fever, urticaria-like reactions, biliary fistula) were seen in 44 treated patients (12%, 44/374); the only major complication was reversible anaphylactic shock which was observed in two patients (0.5%, 2/374). CONCLUSION This novel modified PAIR technique may be superior to catheterization by Seldinger technique due to its efficiency, easier application, lower severe complication rate, and lower cost. Further comparative studies are required to confirm our observations.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/gumushane/10497Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.5152/dir.2015.15011Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
24
OpenAlex
32
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorNayman, Alaaddin
dc.contributor.authorGuler, Ibrahim
dc.contributor.authorKeskin, Suat
dc.contributor.authorErdem, Tuba Berra
dc.contributor.authorBorazan, Hale
dc.contributor.authorKucukapan, Ahmet
dc.contributor.authorOzbiner, Huseyin
dc.contributor.authorBatur, Abdussamed
dc.contributor.authorErtekin, Ersen
dc.contributor.authorFeyzioglu, Bahadir
dc.contributor.authorKoc, Osman
dc.contributor.authorKaya, Hasan Emin
dc.contributor.authorTemizoz, Osman
dc.contributor.authorKartal, Adil
dc.contributor.authorOzbek, Orhan
dc.date.accessioned2026-10-22T09:23:01.268277827Z
dc.date.available2026-10-22T09:23:01.268277827Z
dc.date.issued2016-01
dc.description.abstractPURPOSE We aimed to demonstrate the success and reliability of a novel puncture, aspiration, injection, and reaspiration (PAIR) technique in liver hydatid cysts. METHODS Percutaneous treatment with ultrasonographic guidance was performed in 493 hepatic hydatid cysts in 374 patients. Patients were treated with a new PAIR technique by single puncture method using a 6F trocar catheter. The results of this novel technique were evaluated with regards to efficacy and safety of the procedure and complication rates. RESULTS Out of 493 cysts, 317 were Gharbi type I (WHO CE 1) and 176 were Gharbi type II (WHO CE 3A). Of all cysts, 13 were referred to surgery because of cystobiliary fistulization. Recurrence was observed in 11 cysts one month later. Therefore, the success rate of the PAIR technique was 97.7% (469/480). Minor complications (fever, urticaria-like reactions, biliary fistula) were seen in 44 treated patients (12%, 44/374); the only major complication was reversible anaphylactic shock which was observed in two patients (0.5%, 2/374). CONCLUSION This novel modified PAIR technique may be superior to catheterization by Seldinger technique due to its efficiency, easier application, lower severe complication rate, and lower cost. Further comparative studies are required to confirm our observations.
dc.identifier.doi10.5152/dir.2015.15011
dc.identifier.eissn1305-3612
dc.identifier.endpage51
dc.identifier.issn1305-3825
dc.identifier.issue1
dc.identifier.pmid26574902
dc.identifier.startpage47
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/gumushane/10497
dc.identifier.volume22
dc.identifier.wosWOS:000368845900007
dc.language.isoen
dc.publisherAVES
dc.relation.ispartofDIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.classificationRadiology, Nuclear Medicine & Medical Imaging
dc.subject.otherDISEASE
dc.subject.otherECHINOCOCCOSIS
dc.subject.otherALBENDAZOLE
dc.subject.otherINJECTION
dc.titleA novel modified PAIR technique using a trocar catheter for percutaneous treatment of liver hydatid cysts: a six-year experience
dc.typeArticle
rdl.citation.openalex32
rdl.citation.wos24
rdl.oa.statuspreprint
rdl.oa.statusgreen
rdl.oa.urlhttps://www.ncbi.nlm.nih.gov/pmc/articles/4712897
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)