<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-23T14:55:28Z</responseDate><request verb="GetRecord" identifier="oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/15876" metadataPrefix="oai_dc">https://gumushane-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/15876</identifier><datestamp>2026-10-22T11:38:17Z</datestamp><setSpec>openaire</setSpec><setSpec>com_gumushane_10000</setSpec><setSpec>col_gumushane_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Determination of proper peaking time for Ultra-LEGe detector</dc:title><dc:creator>Karabidak, S. M.</dc:creator><dc:creator>Kaya, S.</dc:creator><dc:creator>Çevik, U.</dc:creator><dc:creator>Çelik, A.</dc:creator><dc:subject>Pile-up</dc:subject><dc:subject>Peaking time</dc:subject><dc:subject>Resolving time</dc:subject><dc:subject>Dead time</dc:subject><dc:subject>Ultra-LEGe detector</dc:subject><dc:description>Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the proper peaking time for particular detector systems is important. The characteristic X-rays emitted from pure some elements were detected by using an Ultra-LEGe detector connecting a Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by an HM 203-7 oscilloscope connecting amplifier. The proper peaking time for Ultra-LEGe is determined as 3.84 mu s. (C) 2011 Elsevier Ltd. All rights reserved.</dc:description><dc:publisher>PERGAMON-ELSEVIER SCIENCE LTD</dc:publisher><dc:date>2011-04</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/gumushane/15876</dc:identifier><dc:identifier>https://doi.org/10.1016/j.radmeas.2011.01.023</dc:identifier><dc:identifier>1350-4487</dc:identifier><dc:language>en</dc:language><dc:relation>RADIATION MEASUREMENTS</dc:relation><dc:rights>info:eu-repo/semantics/closedAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://gumushane-rdlopen.rawdatalibrary.net/tr/items/gumushane/15876</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>