<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-24T17:16:42Z</responseDate><request verb="GetRecord" identifier="oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/15703" metadataPrefix="oai_dc">https://gumushane-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/15703</identifier><datestamp>2026-10-23T21:05:42Z</datestamp><setSpec>openaire</setSpec><setSpec>com_gumushane_10000</setSpec><setSpec>col_gumushane_10001</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Evaluation of energy absorption of macro synthetic and steel fiber reinforced concretes; [Evaluarea capacitătii de absorbţie a energiei de către betonul armat cu fibre macro sintetice şi fibre de oţel]</dc:title><dc:creator>Bolat, Hakan</dc:creator><dc:creator>Şìmşek, Osman</dc:creator><dc:subject>Energy absorption</dc:subject><dc:subject>Fiber reinforced concrete</dc:subject><dc:subject>Slab test</dc:subject><dc:subject>Steel fiber</dc:subject><dc:subject>Synthetic fiber</dc:subject><dc:description>This study aims to determine the energy absorption of concrete slabs (60×60×10cm) using polyester, polypropylene and steel fiber reinforced (SFRC, PYFRC, PPFRC) according to EN 14488-5. Significant differences in the energy absorption were observed between the concrete slabs strengthened with different fibers. The highest gain in energy absorption was observed in SFRC. Furthermore, concrete slabs strengthened with PPFRC and PYFRC showed 23.4% and 14.8% less energy to SFRC. Although the SFRC showed the highest energy absorption under directly negative conditions, it is important to evaluate the durability issues associated with SFRC, such negative conditions.</dc:description><dc:publisher>Procema SA</dc:publisher><dc:date>2015</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/gumushane/15703</dc:identifier><dc:identifier>1583-3186</dc:identifier><dc:language>en</dc:language><dc:relation>Revista Romana de Materiale/ Romanian Journal of Materials</dc:relation><dc:rights>info:eu-repo/semantics/closedAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://gumushane-rdlopen.rawdatalibrary.net/tr/items/gumushane/15703</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>