<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-23T16:02:44Z</responseDate><request verb="GetRecord" identifier="oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/15031" metadataPrefix="oai_dc">https://gumushane-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/15031</identifier><datestamp>2026-10-22T11:37:38Z</datestamp><setSpec>openaire</setSpec><setSpec>com_gumushane_10000</setSpec><setSpec>col_gumushane_10001</setSpec><setSpec>com_gumushane_10007</setSpec><setSpec>col_gumushane_10171</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>The determination of the pulse pile-up reject (PUR) counting for X and gamma ray spectrometry</dc:title><dc:creator>Karabidak, S.M.</dc:creator><dc:creator>Kaya, S.</dc:creator><dc:contributor>Akkus, B.</dc:contributor><dc:contributor>Dogan, G.S.</dc:contributor><dc:contributor>Oktem, Y.</dc:contributor><dc:contributor>Guzelcimen, F.</dc:contributor><dc:description>The collection the charged particles produced by the incident radiation on a detector requires a time interval. If this time interval is not sufficiently short compared with the peaking time of the amplifier, a loss in the recovered signal amplitude occurs. Another major constraint on the throughput of modern x or gamma-ray spectrometers is the time required for the subsequent the pulse processing by the electronics. Two above-mentioned limitations are cause of counting losses resulting from the dead time and the pile-up. The pulse pile-up is a common problem in x and gamma ray radiation detection systems. The pulses pile-up in spectroscopic analysis can cause significant errors. Therefore, inhibition of these pulses is a vital step. A way to reduce errors due to the pulse pile-up is a pile-up inspection circuitry (PUR). Such a circuit rejects some of the pulse pile-up. Therefore, this circuit leads to counting losses. Determination of these counting losses is an important problem. In this work, a new method is suggested for the determination of the pulse pile-up reject.</dc:description><dc:publisher>American Institute of Physics Inc.</dc:publisher><dc:date>2017</dc:date><dc:type>Conference Object</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/gumushane/15031</dc:identifier><dc:identifier>https://doi.org/10.1063/1.4976408</dc:identifier><dc:identifier>978-073541483-9</dc:identifier><dc:identifier>0094-243X</dc:identifier><dc:language>en</dc:language><dc:relation>AIP Conference Proceedings</dc:relation><dc:rights>info:eu-repo/semantics/closedAccess</dc:rights><dc:type>info:eu-repo/semantics/conferenceObject</dc:type><dc:identifier>https://gumushane-rdlopen.rawdatalibrary.net/tr/items/gumushane/15031</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>