<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-23T16:03:59Z</responseDate><request verb="GetRecord" identifier="oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/13021" metadataPrefix="oai_dc">https://gumushane-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/13021</identifier><datestamp>2026-10-22T11:35:55Z</datestamp><setSpec>openaire</setSpec><setSpec>com_gumushane_10000</setSpec><setSpec>col_gumushane_10001</setSpec><setSpec>com_gumushane_10007</setSpec><setSpec>col_gumushane_10171</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Effect of detuning conditions on the performance of non-traditional tuned mass dampers under external excitation</dc:title><dc:creator>Araz, Onur</dc:creator><dc:subject>Non-traditional</dc:subject><dc:subject>Optimal design</dc:subject><dc:subject>Robustness</dc:subject><dc:subject>Tuned mass damper</dc:subject><dc:subject>Vibration control</dc:subject><dc:description>The tuned mass damper (TMD) is a widely used passive control device which is attached to a main system to suppress undesired vibration. In this paper, a non-traditional form of TMD system is investigated. Unlike the traditional TMD configuration, the considered TMD system has a linear viscous damper connecting the absorber mass directly to the ground instead of the main mass. There have been some studies on the optimization design of the non-traditional TMD (NT-TMD) for undamped main structures. Those studies have indicated that the NT-TMD provides better performance than the traditional TMD does. When there is a frequency shifting in the structural frequency or tuning frequency of TMD, to the best knowledge of the authors, there has been no study on the performance of the NT-TMD. The main idea of the study is to investigate the effect of frequency detuning on the control performance of the NT-TMD. The optimum parameters of the NT-TMD system and corresponding effectiveness are obtained for different mass ratios of the NT-TMD system. The numerical results indicate that the NT-TMD with high mass ratio provides better robustness to the changes in the target frequency ratio than the traditional TMD.</dc:description><dc:publisher>Springer</dc:publisher><dc:date>2020</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/gumushane/13021</dc:identifier><dc:identifier>https://doi.org/10.1007/s00419-019-01623-z</dc:identifier><dc:identifier>0939-1533</dc:identifier><dc:language>en</dc:language><dc:relation>Archive of Applied Mechanics</dc:relation><dc:rights>info:eu-repo/semantics/closedAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://gumushane-rdlopen.rawdatalibrary.net/tr/items/gumushane/13021</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>