<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-24T16:22:23Z</responseDate><request verb="GetRecord" identifier="oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/12610" metadataPrefix="oai_dc">https://gumushane-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/12610</identifier><datestamp>2026-10-23T21:02:16Z</datestamp><setSpec>openaire</setSpec><setSpec>com_gumushane_10000</setSpec><setSpec>col_gumushane_10001</setSpec><setSpec>com_gumushane_10007</setSpec><setSpec>col_gumushane_10171</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Effect of detector crystal size on Compton suppression factors</dc:title><dc:creator>Kaya, Selim</dc:creator><dc:creator>Çelik, Necati</dc:creator><dc:creator>Gök, Abdulkadir</dc:creator><dc:creator>Çevik, Uğur</dc:creator><dc:subject>Compton suppression factor</dc:subject><dc:subject>EGS4 code</dc:subject><dc:subject>HPGe detector</dc:subject><dc:description>The geometrical parameters which affect the suppression factor for an HPGe (High Purity Germanium)-NaI Compton suppression spectrometer were studied by a Monte Carlo simulation with the EGS4 system. The spectrums were crated for 5 energy values ranging from 200 keV to 2 MeV. Compton suppression factors (CSFs), the parameters characterizing the system performance, were calculated for different HPGe crystal parameters. It was observed that to obtain better Compton suppressed factors, a laboratory must choose as small HPGe crystal as possible for energy values up to 400 keV. However, for higher energies up to 2 MeV, larger HPGe crystals provide better Compton suppression systems. These findings suggest that the choice of HPGe crystal size can significantly impact the performance of a Compton suppression spectrometer and should be carefully considered in its design and optimization.</dc:description><dc:publisher>Taylor and Francis Ltd.</dc:publisher><dc:date>2023</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/gumushane/12610</dc:identifier><dc:identifier>https://doi.org/10.1080/10420150.2023.2258432</dc:identifier><dc:identifier>1042-0150</dc:identifier><dc:language>en</dc:language><dc:relation>Radiation Effects and Defects in Solids</dc:relation><dc:rights>info:eu-repo/semantics/closedAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://gumushane-rdlopen.rawdatalibrary.net/tr/items/gumushane/12610</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>