<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-23T19:51:57Z</responseDate><request verb="GetRecord" identifier="oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/11547" metadataPrefix="oai_dc">https://gumushane-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:gumushane-rdlopen.rawdatalibrary.net:gumushane/11547</identifier><datestamp>2026-10-23T18:11:37Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_gumushane_10000</setSpec><setSpec>col_gumushane_10001</setSpec><setSpec>com_gumushane_10007</setSpec><setSpec>col_gumushane_10180</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Highly Efficient Spectrophotometric Determination of Cu2+ ion in Aqueous Medium Using a thiosemicarbazone–derivative Ligand</dc:title><dc:creator>Başoğlu, Aysel</dc:creator><dc:creator>Ocak, Ümmühan</dc:creator><dc:creator>Iyidoğan, Ayşegül Karaküçük</dc:creator><dc:subject>Aqueous medium</dc:subject><dc:subject>Cu&lt;sup&gt;2+&lt;/sup&gt;</dc:subject><dc:subject>spectrophotometric determination</dc:subject><dc:subject>Thiosemicarbazone derivative</dc:subject><dc:description>A new simple spectrophotometric method for the determination of Cu2+ ion was developed using an thiosemicarbazone compound, 2-{4-[Bis(2-chloroethyl)amino]benzylidene}-N-[(4-methylthio)phenyl]hydrazinecarbothioamide (TSC). A simultaneous color change was observed (from colorless to bright yellow) by the addition of Cu2+ ion to the TSC ligand solution. The maximum absorbance of the TSC ligand measured at 366 nm was decreased by the presence of Cu2+ ion. The graphs of absorbance obtained by means of the Job’s method and the molar-ratio method proposed a complex formation with a 1:2 Cu2+–TSC ligand stoichiometry. The molar-ratio method with emission measurements also confirmed the stoichiometry. The complex stability constant of TSC–Cu2+ complex (K) was evaluated to be 1.76 × 105. The proposed spectrophotometric method was associated with the change in absorbance at 366 nm owing to the interaction between the TSC ligand and Cu2+ ion. From the spectrophotometric titration data, it was pointed out that TSC ligand (1.5 × 10− 5 mol L-1) selectively reacted with Cu2+ ion in DMSO/water (1:1, v/v, citrate buffer at pH = 6.0). The calibration curve for Cu2+ ion was obtained with a good linearity in the range of 0.0191–0.3241 mg L-1. The detection limit for Cu2+ ion was 0.0063 mg L-1. The proposed method was achievemently implemented in real water samples (drink water, tap water and, distilled water). Satisfactory recoveries were confirmed at three different concentrations. The method presented a relative standard deviation (RSD%) of less than 3.08%.</dc:description><dc:publisher>Springer</dc:publisher><dc:date>2023</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/gumushane/11547</dc:identifier><dc:identifier>https://doi.org/10.1007/s10895-022-03127-6</dc:identifier><dc:identifier>1053-0509</dc:identifier><dc:language>en</dc:language><dc:relation>Journal of Fluorescence</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://gumushane-rdlopen.rawdatalibrary.net/tr/items/gumushane/11547</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>